![EINHELL BT-PG 4000 Original Operating Instructions Download Page 16](http://html1.mh-extra.com/html/einhell/bt-pg-4000/bt-pg-4000_original-operating-instructions_2371000016.webp)
GB
16
9. Troubleshooting
Fault
Cause
Remedy
Engine does not start
Automatic oil cut-out has not
responded
Spark plug fouled
No fuel
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / have the petrol cock
checked
Generator has too little or no
voltage
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air filter dirty
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter