GB
- 10 -
10. Charger indicator
Indicator status
Explanations and actions
Red LED
Green LED
O
ff
Flashing
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
On
O
ff
Charging
The charger is charging the battery pack in quick charge mode.
O
ff
On
The battery pack is fully charged (charging completed)
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Flashing
O
ff
Adapted charging
The charger is in gentle charging mode. For safety reasons the char-
ging is performed less quickly and takes more than 1 hour. The rea-
sons can be:
- The battery pack has not been used for a very long time or an alrea-
dy
fl
at battery was further discharged (exhaustive discharge)
- The battery pack temperature is outside the ideal range (between
10° C and 45° C).
Action:
Wait for the charging to be completed; you can still continue to charge
the battery pack.
Flashing
Flashing
Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack. Take the battery pack out of the
charger.
On
On
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature
(approx. 20° C) for one day.
Anl_TC-CD_12-2_Li_SPK7.indb 10
Anl_TC-CD_12-2_Li_SPK7.indb 10
07.04.2017 08:35:26
07.04.2017 08:35:26