background image

7

GB

Replacing the mains line

of the pump must be performed by a
trained technician

1. Loosen shell screws (2 screws).

2. Unscrew strain relief device.

3. Loosen mains connection clamp on 

the switch and protective wire 
connection screw on the motor shell.

4. Thread new mains cable (line type 

H07 RN- F3G 1.0 or 1.5) with 
prepared ends through the socket 
and secure with strain relief clamp 
from becoming disconnected.

5. It is absolutely necessary that the 

protective conductor should be sub-
stantially longer than both the other 
conductors. Should the mains cable 
be accidentally pulled out, the pro-
tective conductor must be the last 
which is pulled free from the clamp.

6. Manually check the clamp and strain

relief device.

7. Reassemble the shell halves.

8. Perform a trial run.

Spare parts ordering
instructions

If you should requiring spare parts for
your pump at a later time, we request
you to give the following information
when ordering:

1. Pump type
2. Identification number
3. Amount 
4. Positions number
5. Designation of spare part
6. Spare part number

Disturbances

1. Motor does not run

Causes

Remedy

– Mains voltage missing

– Check voltage

– Pump wheel blocked – thermal

– Disassemble pump and clean

– 

guards has shut off

2. Not pump intake

Causes

Remedy

– Suction valve not in water

– Place suction valve in water

– Pump champer is without water

– Put water into intake connection

– There is air in the suction line

– check for leakage in suction line

– Suction valve leaks

– Clean suction valve

– Suction basket (suction valve) is

– Clean suction basket

– 

blocked

– Max. intake height execeeded

– Check intake height

3. Transport volume insufficient

Causes

Remedy

– Intake height too hight

– Check intake height

– Suction basket contaminated

– Clean suction basket

– Water level quickly drops

– Place suction valve lower

– Pump performance reduced

– Clean pump and replace worn

– 

becaus of contaminants

– 

out parts

4. Thermal pump switches pump off

Causes

Remedy

– Motor overloaded, friction from

– Disassemble pump and clean,

– 

foreign material too high

– 

prevent intake of foreign

– 

materials

ATTENTION!
The pump must not be allowed to run dry.

Technical data:

Mains connection:

230 V ~ 50 Hz

Capacity:

800 Watt

Alternating current, asynchronous motor rotation:

2850 U/min.

Transport height:

40 m

Transport volume max.:

2600 l/h

Transport pressure max.:

4 bar

Intake height max.:

8 m

Water temperature max.:

40° C

Suction and pressure connection internal screw thread

R 1”

Anleitung GP Jet 800 Niro  13.11.2001 15:13 Uhr  Seite 7

Summary of Contents for 41.710.30

Page 1: ...GP JET800 GP NIRO Bedienungsanleitung Universalpumpe Operation manual Universal pump Notice d utilisation Pompe universelle Art Nr 41 710 30 Anleitung GP Jet 800 Niro 13 11 2001 15 13 Uhr Seite 1...

Page 2: ...3 EEC EG Richtlinie Einfache Druckbeh lter 87 404 EWG EC Direktive for easy pressure tank 87 404 EWG EG Richtlinie Elektromagnetische Vertr glichkeit 89 336 EWG mit nderungen EC direktive electromagne...

Page 3: ...3 Selbstansaugend bis 6 m Self priming up to 6 m Autoaspirante jusqu 6 m Anleitung GP Jet 800 Niro 13 11 2001 15 13 Uhr Seite 3...

Page 4: ...nd verhindern den Ansaugvorgang Saug und Druckleitung sind so anzu bringen da diese keinen mechani schen Druck auf die Pumpe aus ben Das Saugventil sollte gen gend tief im Wasser liegen soda durch Abs...

Page 5: ...pannung fehlt Spannung berpr fen Pumpenrad blockiert Thermo Pumpen zerlegen und reinigen w chter hat abgeschaltet 2 Pumpe saugt nicht an Ursachen Beheben Saugventil nicht im Wasser Saugventil im Wasse...

Page 6: ...tion to the pump at a rising angle It is absolutely necessary to avoid installing the suction line above pump level since air bubbles in the suction line delay and prevent intake The suction and press...

Page 7: ...ck voltage Pump wheel blocked thermal Disassemble pump and clean guards has shut off 2 Not pump intake Causes Remedy Suction valve not in water Place suction valve in water Pump champer is without wat...

Page 8: ...ocessus d aspiration Les tuyaux d aspiration et de refoulement sont monter de telle fa on qu il n exercent pas de pression m canique sur la pompe La soupape d aspiration doit e tre situ e une profonde...

Page 9: ...aspire pas de liquide Causes Rem des La soupape d aspiration n est pas Ajuster la soupape d aspiration dans l eau dans l eau Pas d eau dans la cavit de Rempir d eau le raccord la pompe d aspiration P...

Page 10: ...10 Ersatzteilzeichnung GP JET 800 NIRO Art Nr 41 710 30 I Nr 91015 Anleitung GP Jet 800 Niro 13 11 2001 15 13 Uhr Seite 10...

Page 11: ...Gewindenippel R 1 41 712 30 19 20 O Ring 41 712 30 20 21 Motorgeh use mit Stator 41 710 30 05 22 Motorflanschschraube 41 712 30 22 23 Netzleitung 41 710 30 06 24 Befestigungsschraube 41 710 30 07 25 T...

Page 12: ...ar Germany Ersatzteil und Reparatur Abt Telefon 0 99 51 942 357 Telefax 0 99 51 26 10 und 52 50 Technische Kundenberatung Telefon 0 99 51 942 358 Technische nderungen vorbehalten Technical changes sub...

Reviews: