GB
- 19 -
5. Before starting the equipment
5.1 Assembly
•
Assemble the foot, wheels and push bar as
shown in Figures 6-9.
•
Assemble all parts before filling in fuel and oil
in order to prevent the fluids from leaking out.
•
To mount the wheels, first slide the axle
through the mountings on the bottom of the
generator and fit the wheels as shown on
Figure 7.
5.2 Electrical safety:
•
Electric supply cables and connected equip-
ment must be in perfect condition.
•
The generator is to be operated only with
•
equipment whose voltage specifications con-
form with the generators output voltage.
•
Never connect the generator to the power
supply (socket-outlet).
•
Keep the cable length to the consumer as
short as possible.
5.3 Environmental protection
•
Dispose of soiled maintenance material and
•
operating materials at the appropriate collec-
tion point.
•
Recycle packaging material, metal and plas-
tics.
5.4 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth connec-
tion on the generator (Fig. 4) and the other end to
an external earth (for example an earthing rod).
6. Operation
Important!
You must ll up with engine oil and
fuel before you can start the engine.
•
Check the fuel level and top it up if necessary
•
Make sure that the generator has sufficient
ventilation
•
Make sure that the ignition cable is secured to
the spark plug
•
Inspect the immediate vicinity of the gene-
rator
•
Disconnect any electrical equipment which
may already be connected to the generator
6.1 Starting the engine
•
Open the petrol cock (13) by turning it down
•
Move the ON/OFF switch (10) to position
ON with the key.
•
Move the choke lever (11) to position IØI.
•
Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
•
Push the choke lever (11) back again after
the engine has started.
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting in
hand injuries. Wear protective gloves when star-
ting the equipment.
6.2 Connecting consumers to the generator
•
Connect the equipment you want to use to
the 230 V~sockets (3).
Important:
These sockets may be loaded con-
tinuously (S1) with 2600W and temporarily (S2)
for a maximum of 5 minutes with 2800 W or for a
maximum of 2 minutes (with a cold motor) with
3100W.
•
The generator is suitable for 230 V~ AC appli-
ances only.
•
Do not connect the generator to the
household mains system as this may result
in damage to the generator itself or to other
electrical appliances in your home.
Note:
Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in di cult conditions.
Some electrical appliances (for example televisi-
ons, computers, etc.) must not be powered by a
generator.
If in doubt, consult the manufacturer of your ap-
pliance.
6.3 Overload cut-out 2 x 230 V socket-outlets
Important! The generator is tted with an
overload cut-out.
This shuts down the sockets (3). You can restart
the sockets (3) by pressing the overload cut-out
(5).
Important!
If this happens, reduce the electric
power you are taking from the generator or remo-
ve any defective connected appliances.
Important!
Defective overload cut-outs must be
replaced only by overload cut-outs of identical
Summary of Contents for 41.525.51
Page 2: ... 2 1 2 10 8 7 2 1 3 13 10 3 8 5 4 12 11 7 9 14 6 ...
Page 4: ... 4 10 11 12 13 7 9 8 A A B C D 14 1 2 3 4 6 5 7 ...
Page 116: ...RUS 116 14 1 2 3 4 5 6 7 1 1 ...
Page 117: ...RUS 117 H07RN 1 5 1 5 60 2 5 100 10 40 1000 90 ISO 8528 IEC 60245 4 ...
Page 120: ...RUS 120 S2 5 min 5 min 5 5 1 6 9 7 5 2 5 3 5 4 3 4 6 6 1 13 10 ON 11 I Ø I 12 11 6 2 230 3 ...
Page 121: ...RUS 121 S1 2600 S2 5 2800 2 3100 230 6 3 6 4 1 10 ST P 7 7 1 7 2 10 A 10 B 11 C ...
Page 122: ...RUS 122 7 3 10 50 7 4 7 5 7 6 7 5 5 7 8 www isc gmbh info 8 9 ...
Page 123: ...RUS 123 10 0 6 ...
Page 124: ...RUS 124 2012 19 EG ISC GmbH pa e c a e e e ...
Page 125: ...RUS 125 www isc gmbh info ...
Page 126: ...RUS 126 1 2 3 4 24 5 www isc gmbh info ...
Page 157: ...GR 157 14 1 2 3 4 5 6 7 1 N 1 H07RN 1 5 1 5 mm 60 m 2 5 mm 100 m ...
Page 158: ...GR 158 10 40 1000m 90 ISO 8528 IEC 60245 4 ISO 8528 8 LWA LWM ...
Page 162: ...GR 162 7 2 11 11 B 12 C 7 3 10 50 13 D 7 4 7 5 7 4 7 6 7 7 5 7 8 www isc gmbh info ...
Page 163: ...GR 163 8 9 o ...
Page 164: ...GR 164 10 0 6 mm ...
Page 165: ...GR 165 2012 19 iSC GmbH M ...
Page 166: ...GR 166 www isc gmbh info ...
Page 167: ...GR 167 1 2 3 4 24 5 www isc gmbh info ...
Page 169: ... 169 ...
Page 170: ...EH 06 2019 01 ...