6.3 Switching off the engine
Before you switch off the generator, allow it to run
briefly with no consumers so that it can “cool
down”
Move the ON/OFF switch (7) to position “0”
Turn the petrol cock (4) to position “0”.
Important. The generator is fitted with an over-
load cut-out.
This shuts down the 230V~ socket (3). You can
restart the socket (3) by pressing the overload cut-
out (6).
Important. If this happens, reduce the electric
power you are taking from the generator.
6.4 Connecting to earth
The generator must be earthed to prevent an electric
shock from electrical equipment. Connect a piece of
cable between the earth connection on the generator
and an external earth point.
7. Maintenance
Remove dust and dirt from the machine at regular
intervals. The best tools for cleaning are a fine
brush or a cloth
Do not use any caustic substances to clean the
plastic
Take the petrol mixture out of the generator if you
do not intend to use the generator for a lengthy
period of time
Important. Switch off the machine immediately
and contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or misfires
If the emissions are too dark or too light
The generator must be earthed to prevent an electric
shock from electrical equipment. Connect a piece of
cable between the earth connection on the generator
and an external earth point.
8. TECHNICAL DATA
Generator Synchronous
Protection type
IP 23
Continuous power
650 VA / 650 W
Maximum power
Rated voltage
230 V / 1
Rated current
2.8 A / 1
Frequency 50
Hz
Drive engine design
1-cyl. 2-stroke, air-cooled
Displacement 63
cc
Max. power
FuelMixture 1:50
(2%)
Tank capacity
4.0 l
Consumption at 3/4 load
approx. 0.7 l/h
Weight 20.5
kg
Sound power level LWA
9
4
dB(A)
Sound pressure level LWM
89 dB(A)
9. Circuit diagram STE 800
Description
Symbol
Field coil
FC
Rectifier
D1
Secondary coil
SC
Capacitor
C
Main coil
MC
Load switch
AC Reset
GB
6
Anleitung STE 800 30.04.2003 7:16 Uhr Seite 6
0.95
KW /
1.3
hp
80
0 VA /
80
0 W
/S
2
/15min