background image

GB

7

You can then see whether the equipment
switches on and off.

Make sure that the distance between the floating
switch head and the cable holder is not too small.
If the distance is too small, there is no guarantee
that the equipment will work correctly.

When adjusting the floating switch, make sure
that the floating switch does not touch the bottom
before the equipment is switched off. Important!
Risk of dry running.

7. Replacing the power cable

If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.

8. Cleaning, maintenance and

ordering of spare parts

Important!

Unplug the power plug prior to any maintenance
work.

For mobile applications, the equipment should be
cleaned with clear water after every usage.

For stationary installation, it is recommended that
you check the floating switch for proper
functioning every three months.

Use a water jet to remove any lint or fibrous
particles that may have become trapped in the
housing.

Remove sludge from the shaft bottom and clean
the shaft walls every 3 months.

Use clear water to remove deposits from the
floating switch.

8.1 Cleaning the filter (Figs. 7 and 8)

In order to protect the equipment and the impeller
from severe soiling, an additional filter has been
installed in the bottom intake cage. Please proceed
as follows when cleaning the filter:
1.  Gently press the lateral tab (A) in the direction of

the arrow until the intake cage (5) can be
disconnected from the pump.

2.  Remove the filter (B) and wash it out under

running water.

3.  Now insert the filter back into the intake cage and

reconnect the intake cage to the equipment.

8.2 Maintenance

There are no parts inside the equipment which 
require additional maintenance.

8.3 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:

Type of machine

Article number of the machine

Identification number of the machine

Replacement part number of the part required

For our latest prices and information please go to
www

.einhell.com.au��

9. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.

Anleitung_BG_SP_400_RB_SPK1:_  04.07.2008  11:04 Uhr  Seite 11

Summary of Contents for 400 RB

Page 1: ...Operating Instructions Rain Barrel Pump Art Nr 41 703 04 I Nr 11010 BG SP 400 RB Anleitung_BG_SP_400_RB_SPK1 _ 04 07 2008 11 03 Uhr Seite 1...

Page 2: ...2 Read and follow the operating instructions and safety information before using for the first time Anleitung_BG_SP_400_RB_SPK1 _ 04 07 2008 11 03 Uhr Seite 2...

Page 3: ...3 2 1 2 1 5 3 4 7 10 8 9 6 3 5 4 6 9 6 7 10 8 6 7 A 10 8 6 10 7 A Anleitung_BG_SP_400_RB_SPK1 _ 04 07 2008 11 04 Uhr Seite 3...

Page 4: ...4 8 7 5 A B 5 Anleitung_BG_SP_400_RB_SPK1 _ 04 07 2008 11 04 Uhr Seite 4...

Page 5: ...supply company and work correctly The electrical plug in connections must be protected from wet conditions If there is a risk of flooding place the plug in connections in an area which is safe from fl...

Page 6: ...der the equipment from starting It is necessary therefore to check the equipment regularly carry out trial start ups Note The pump shaft should measure at least 40 x 40 x 50 cm so that the floating sw...

Page 7: ...floating switch 8 1 Cleaning the filter Figs 7 and 8 In order to protect the equipment and the impeller from severe soiling an additional filter has been installed in the bottom intake cage Please pro...

Page 8: ...icient pumping rate Intake sieve clogged Performance reduced due to heavily contaminated and abrasive water impurities Clean intake sieve Clean equipment and replace wear parts The equipment switches...

Page 9: ...by unprofessional installation failure to comply with the operating instructions e g connection to the wrong mains voltage or current type misuse or inappropriate use such as overloading of the produ...

Page 10: ...EH 04 2012 02...

Page 11: ...EH 04 2012 02...

Page 12: ...EH 04 2012 02...

Reviews: