GB
- 15 -
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Features
The fan and compressor switch o
ff
once the pre-
set room humidity has been reached. The fan and
compressor switch on again whenever the preset
room humidity is exceeded.
5.1 Description of the control panel (Fig. 2)
11 “Voltage present” LED (Power)
12 “Condensate collector full” LED (Water full)
13 “Automatic air outlet adjuster” LED (Swing)
14 “Timer” LED (Timer)
15 “Humidity settings” LED (Settings)
16 “High fan speed” LED (High)
17 “Low fan speed” LED (Low)
18 Indicator panel LED
21 On/O
ff
switch (Power)
22 “Automatic air outlet adjuster” switch (Swing)
23 “Timer settings” switch (Timer)
24 “Higher/lower” switch (
Δ∇
)
25 “Humidity settings” switch (Settings)
26 “Fan speed” switch
The following information is displayed in the LED
indicator panel (Item 18):
•
If the device is supplied with mains voltage,
the prevailing humidity level at the integrated
sensor will be displayed in percent.
•
The set value is displayed in percent during
the setting of the humidity.
•
The set value is displayed in hours during the
setting of the timer.
•
If the prevailing humidity at the integrated
sensor is below 35%, “LO” is displayed.
•
If the prevailing humidity at the integrated
sensor is above 95%, “HI” is displayed.
The LEDs shine when the function has been set
(Item 11 – 17).
The device will switch o
ff
automatically when the
condensate collector is full.
Provision has also been made for the condensate
to be drained o
ff
continuously if preferred.
Principle of operation
The dehumidi
fi
er monitors the relative humidity
of the inlet air. The humidity condenses on the
cooling elements and is directed into the water
collector. The dry air – warmed slightly at the
condenser – is returned to the room. A refrigerant
compressor is needed for the dehumidi
fi
er’s ope-
ration.
Note:
•
The room temperature must lie in the range
from 5 to 35 °C and the room humidity must
lie in the range from 40 to 95 % RH. The de-
humidifier does not work outside this range.
•
To achieve an optimum circulation of air you
should set up the equipment in the middle of
the room if at all possible.
•
Avoid opening windows and doors, avoid en-
tering and leaving the room frequently, etc.
•
The equipment must not be used in environ-
ments containing lots of dust or chlorine.
•
The dehumidifier’s performance depends
on the room’s conditions, temperature and
humidity.
•
If the condensate collector is not fitted cor-
rectly, the equipment will not work.
•
To prevent high starting currents, the equip-
ment has a restart inhibit function which does
not allow the compressor to be switched on
again until after a waiting period of 3 minutes.
6. Operation
The LEDs shine when the function has been set
(Item 11 – 17).
The air outlet opens automatically after the device
has been switched on.
1. If the device is supplied with mains voltage,
the “Power” LED shines (Fig. 2 / Item 11).
2. To switch on, press the On/O
ff
switch (Fig. 2 /
Item 21). The air outlet opens automatically, a
humidity level of 60% and a low fan speed are
already preset.
3.
Automatic air outlet adjuster
To switch on the air outlet adjuster, press the
SWING switch (Fig. 2 / Item 22). The air outlet
adjusts automatically up and down. To
fi
x an
air outlet setting, press the SWING switch
again. Do not adjust the air outlet manually.
Anl_LE_16_20_30_SPK7.indb 15
Anl_LE_16_20_30_SPK7.indb 15
24.02.16 08:33
24.02.16 08:33
Summary of Contents for 23.690.22
Page 3: ...3 4 5 6 7 B C D...
Page 81: ...GR 81 1 1 0 5 m 8 2 2 1 1 1 2 3 4 5 6 7 8 9 10 2 2...
Page 85: ...GR 85 1 1 1 2 8 4 1 2 C 10 mm 21 C 35 C 5 C 9 2 5 7 5 6 40 C 5 D...
Page 86: ...GR 86 8 www isc gmbh info 10 N 5 30 C 11...
Page 87: ...GR 87 2012 19 iSC GmbH M...
Page 88: ...GR 88 1 2 3 4 24 5 www isc gmbh info...
Page 89: ...BG 89 1 1 0 5 8 2 2 1 1 1 2 3 4 5 6 7 8 9 10 2 2...
Page 93: ...BG 93 1 1 1 2 8 4 1 1 2 B C 10 21 C 35 C 5 C 9 2 5 7 5 6 40 C 5 D 8...
Page 94: ...BG 94 www isc gmbh info 10 5 30 C 11...
Page 95: ...BG 95 l 2012 19 EO iSC GmbH...
Page 96: ...BG 96 1 2 3 4 24 5 www isc gmbh info...
Page 100: ...EH 02 2016 01...