![Eiki LC-XB100A Service Manual Download Page 45](http://html1.mh-extra.com/html/eiki/lc-xb100a/lc-xb100a_service-manual_2369457045.webp)
-45-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
8 DIMMER_CTRL_LEVEL9
Luminance Level 9 Data for Dimmer:
Dim Level 9 at the less than the
Value
63
0-255
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for
Dimmer: Dim Level 10 at the less
than the Value
70
0-255
10 DIMMER_CTRL_LEVEL11
Luminance Level 11 Data for
Dimmer: Dim Level 11 at the less
than the Value
77
0 - 255
11 DIMMER_CTRL_LEVEL12
Luminance Level 12 Data for
Dimmer: Dim Level 12 at the less
than the Value
84
0 - 255
12 DIMMER_CTRL_LEVEL13
Luminance Level 13 Data for
Dimmer: Dim Level 13 at the less
than the Value
91
0 - 255
13 DIMMER_CTRL_LEVEL14
Luminance Level 14 Data for
Dimmer: Dim Level 14 at the less
than the Value
98
0 - 255
14 DIMMER_CTRL_LEVEL15
Luminance Level 15 Data for
Dimmer: Dim Level 15 at the less
than the Value
105
0 - 255
15
DIMMER_AVERAGE_POINT
Luminance Data Avarage Point for
Mimmer
4
0 - 16
16 DIMMER_AVERAGE_DATA
Luminance Data Avarage Value for
Dimmer
-
-
* Read only
17 DIMMER_LEVEL_AUTO
Current Dimmer Leverl
-
-
* Read only
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level
8
0 - 15
19 DIMMER_LEVEL_ECO
Eco Dimmer Level
0
0 - 15
20 Lamp check enable
0
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
21 VOLTAGE_LEVEL
Lamp Voltage
-
Unit: 8bit(Raw Data) * Read only
22 DIMMER_LEVEL_HIGH
Dimmer level High
15
0 - 15
Group
231
VBI Slice Level
0 Generic Initial Slicing Level
PW190 register 0xE344
0x34
0-255
1 Generic High Level Threshold PW190 register 0xE345
--
0-255
2 Generic Low Level Threshold PW190 register 0xE346
--
0-255
3 Generic Minimum Low Level PW190 register 0xE347
0x30
0-255
4 Generic Maximum High Level PW190 register 0xE348
0xe0
0-255
Group
250
FaN control
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
10
0 - 255
1 FAN1 MAX ADJUST (DAC)
225
0 - 255
2 FAN2 MIN ADJUST (DAC)
10
0 - 255
3 FAN2 MAX ADJUST (DAC)
225
0 - 255
4 FAN3 MIN ADJUST (DAC)
15
0-255
5 FAN3 MAX ADJUST (DAC)
255
0-255
6 Not used
7 Not used
Group
251
Not used
Group
252
Fan option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-3
0
0 - 5
1 SAFETY SWITCH
For test purpose
0
0 - 6
2 FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100
0 - 255
4 FAN2 MANUAL VOLTAGE
100
0 - 255
5 FAN3 MANUAL VOLTAGE
100
0 - 255
6 Not used
-
Group
253
Fan tem error Setting (Memorized)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
44
44
44
44
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
60
60
60
60
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
60
60
60
60
30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
Summary of Contents for LC-XB100A
Page 23: ... 23 Optical Parts Disassembly Relay lens disassembly Relay lens Relay lens Ass y Fig 8 ...
Page 65: ... 65 IC Block Diagrams FA5550NG P F Control IC621 XR16L5701IL24 UART IC9885 ...
Page 69: ... 69 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 70: ... 70 IC Block Diagrams FA7703 DC DC Converter IC7811 Sil9127 HDMI Receiver IC8001 ...
Page 97: ...KB5 XB100A00 KG5 XB200A00 97 Mechanical Parts List L14 Projection Lens Projection Lens ...
Page 101: ...KB5 XB100A00 KG5 XB200A00 101 Mechanical Parts List ...
Page 102: ... KB5BE KG5BE December 2009 Japan 2009 Eiki Internatinal Inc A key to better communications ...
Page 114: ...A10 SCH_KD5AE NO DATA ...