![Eiki LC-XB100A Service Manual Download Page 31](http://html1.mh-extra.com/html/eiki/lc-xb100a/lc-xb100a_service-manual_2369457031.webp)
-31-
Electrical Adjustments
1. Enter the service mode.
2. Connect a digital voltmeter to test point “
tPFaNa
”
(+) and chassis ground (-). Select group no. “
250
”,
item no. “
0
” and change data value to adjust voltage
to be
5.0 ±0.1V
.
3. Connect a digital voltmeter to test point “
tPFaNa
”
(+) and chassis ground (-). Select item no. “
1
” and
change data value to adjust voltage to be
13.5
±0.1V
.
4. Connect a digital voltmeter to test point “
tPFaNB
”
(+) and chassis ground (-). Select item no. “
2
” and
change data value to adjust voltage to be
4.5 ±0.1V
.
5. Connect a digital voltmeter to test point “
tPFaNB
”
(+) and chassis ground (-). Select item no. “
3
”
and change data value to adjust voltage to be
13.5
±0.1V
.
6. Connect a digital voltmeter to test point “
tPFaNc
”
(+) and chassis ground (-). Select item no. “
4
” and
change data value to adjust voltage to be
5.0 ±0.1V
.
7. Connect a digital voltmeter to test point “
tPFaNc
” (+)
and chassis ground (-). Select item no. “
5
” and change
data value to adjust voltage to be
13.5 ±0.1V
.
2. Fan control adjustment
1. Enter the service mode.
2. Receive the 16-step grey scale computer signal
with
computer 1 [rGB]
mode.
3. Select group no. “
101
”, item no. “
12
” to ad-
just the voltage of
tP_VMIdG
to be
7.00
±0.01V
.
4. Select group no. “
101
”, item no. “
14
” to adjust
the voltage of
tP35G
to make the amplitude
“
d[Vpp]
” to be
10.00 ±0.05V
.
3 .reference Voltage adjustment
㪛㩷㪲㪭㫇㫇㪴
* Before setting, you need to check which type of LCD
panel is placed on the projector according to the item
"LCD Panel/Prism Ass'y removal" in the chapter "Optical
Parts Disassembly".
1. Enter the service mode.
2. Panel Type Check
Select group no. “
290
”, item no. “
0
”. Check the data
value as follows;
Data value: 0 For L-Type of LCD Panel
Data value: 20 For R-Type of LCD panel
3. Panel Type Setting
Select group no. “
290
”, item no. “
1
” and change
data value from 10 to 0 or 20 depending on your
LCD Panel type. When the data value reaches 0 or
20, it returns to 10 quickly. The gamma-characteris-
tics changes according to your selection.
1. Panel type check and Setting
Note:
Be careful to take this adjustment. The value of
gamma adjustment data will be reset and cannot be
restored if you change the mode of LCD panel type.
After replacing the Power Board readjust the Output
voltage adjustment as follows.
1. Connect a digital voltmeter to RED WIRE (+) and
BLACK WIRE (-).
2. Adjust the voltage by using VR621 as following.
AC Input
Reading
230V
374V �1V
Caution:
Be sure to connect the lamp when taking this adjust-
ment.
* This adjustment is not required even if the power
board is replaced because this adjustment is carried
out before parts shipment.
output Voltage adjustment
Summary of Contents for LC-XB100A
Page 23: ... 23 Optical Parts Disassembly Relay lens disassembly Relay lens Relay lens Ass y Fig 8 ...
Page 65: ... 65 IC Block Diagrams FA5550NG P F Control IC621 XR16L5701IL24 UART IC9885 ...
Page 69: ... 69 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 70: ... 70 IC Block Diagrams FA7703 DC DC Converter IC7811 Sil9127 HDMI Receiver IC8001 ...
Page 97: ...KB5 XB100A00 KG5 XB200A00 97 Mechanical Parts List L14 Projection Lens Projection Lens ...
Page 101: ...KB5 XB100A00 KG5 XB200A00 101 Mechanical Parts List ...
Page 102: ... KB5BE KG5BE December 2009 Japan 2009 Eiki Internatinal Inc A key to better communications ...
Page 114: ...A10 SCH_KD5AE NO DATA ...