-5-
This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the pro-
jector, it will automatically turn off by operating one of the following protection circuits.
Circuit Protections
Fuses are located inside of the projector. When the POW-
ER/LAMP indicators are not lighting, one of the fuses may
be opened. Check the fuses as following steps.
The fuses should be used with the following type;
Location : F601 / F603
Fuse Part No. : 323 025 1204
tYPe 8.0a 250V Fuse
215008, LitteL
How to replace the fuses
1. Remove the cabinet top, Main board, PFC/Ballast Box1-2
following to "Mechanical disassembly".
2. Remove the fuses F601, F602 and F603 on the AC Filter
board.
to install the fuses, take reversed step in the above.
Fuses (F601, F602, F603)
F603
F602
F601
Location : F602
Fuse Part No. : 323 021 7804
tYPe 6.3a 250V Fuse
210506.3, LitteL
AC Filter board