Eighteeth HyperLight User Manual Download Page 34

12 Statement 

 

Page   

34

 / 

35

   

12 Statement 

 

Service Life 

The service life of HyperLight series products is 5 years. 

Maintenance 

MANUFACTURE  will  provide  circuit  diagrams,  component  part  lists, 
descriptions, calibration instructions to assist to SERVICE PERSONNEL in 
parts repair.

 

Disposal 

The package should be recycled. Metal parts of the device are disposed as 
scrap metal. Synthetic materials, electrical components, and printed circuit 
boards are disposed as electrical scrap. Please deal with them according 
to the local environmental protection laws and regulation. 

Rights 

All rights of modifying the product are reserved to the manufacturer without 
further notice. The pictures are only for reference. The final interpretation 
rights  belong  to  CHANGZHOU  SIFARY  MEDICAL  TECHNOLOGY  CO., 
LTD.  The  industrial  design,  inner  structure,  etc,  have  claimed  for  several 
patents  by  SIFARY,  any  copy  or  fake  product  must  take  legal 
responsibilities.

 

 

 

Summary of Contents for HyperLight

Page 1: ...Model HyperLight Hand held Dental X ray System USER MANUAL Changzhou Sifary Medical Technology Co Ltd...

Page 2: ...Version S01 IFU 7035001 Issued 2021 6 1 Size 197mmX140mm...

Page 3: ...ng 11 6 Operation 12 6 1 Operation panel instructions 12 6 12 PowerOn Off 13 6 3 Screen instructions 14 6 4 Set interface 16 6 5 Use of exposure function 17 6 5 Positioning Instructions 18 6 5 1 Paral...

Page 4: ...1 Overview Page 4 35 1 Overview 1 1 Content 4 3 1 2 1 HyperLight Main Body 2 Base 3 Power Adapter with removable power cord 4 Backscatter Radiation Shielding...

Page 5: ...1 Overview Page 5 35 1 2 Packing list and coding HyperLight Main Body 1 pcs Base 1 pcs Power Adapter with removable power cord 1 pcs Backscatter Radiation Shielding option...

Page 6: ...number Type BF applied part Alternating current Dispose of in accordance with the WEEE directive Keep dry 55 C 20 C Temperature limitation 80 20 Humidity limitation 106kPa 70kPa Atmospheric pressure...

Page 7: ...ered justified the practitioner must take the appropriate precautions such as use of radiation safety garments to limit radiation exposure beyond the maxillofacial complex Pediatric The medical practi...

Page 8: ...t lamps radio transmitters remote controls and do not use this system near the active HF Surgical Equipment in the hospital Portable RF communications equipment including peripherals such as antenna c...

Page 9: ...n regulations Pregnant women should not be exposed to X rays unless necessary Proper safety precautions should be taken to minimize dose to the fetus Operators must be fully acquainted with industry s...

Page 10: ...4 Safety Precautions Page 10 35 4 2 Leakage Dose Leakage Dose Permissive Range 65 kVp 2 5 mA 0 5 s Max Exposure Condition At Focal Spot to Distance 1 m 1 30 Duty Cycle 0 25 mGy h...

Page 11: ...ther end into the socket The charging icon will be displayed on the screen at this time External extension cord interface Charging port NOTE Extension cords are not provided 5 2 Install backscatter ra...

Page 12: ...tions Symbol Type Choose adult mode or child mode Choose tooth type Increase exposure time Reduce exposure time Press two buttons at the same time to lock or unlock the machine Press these two buttons...

Page 13: ...Power On 1 First press the power button and then let go then the screen will enter the boot interface 2 Make sure that the battery level is not lower than the figure below Battery level 1 6 2 2 Power...

Page 14: ...2 3 4 5 6 7 No Item Description 1 Bitewing Selects the tooth type Lower Molar Upper Molar Canine Incisor 2 Digital Sensor Use the sensor to receive X rays Phosphor Plate Use the Phosphor Plate to rec...

Page 15: ...cator light starts to red glow it means the battery needs to be charged Battery Charging Indicator Indicates the battery charger is connected to the device 5 Tube Voltage Curre nt Indicator Indicates...

Page 16: ...s at the same time to enter the setting interface press the to turn the page and press the and the to adjust the displayed parameters Display content Meaning Adjust the volume of the machine Select th...

Page 17: ...e the screen will display the inclination angle of the machine to the ground plane and the 60S countdown 3 At this time you need to press and hold the exposure button again for exposure Warning During...

Page 18: ...reen display is finish it means that the exposure has been completed 6 5 Positioning Instructions 6 5 1 Paralleling technique The sensor is placed in a holder which is used to align the sensor paralle...

Page 19: ...or in place with his her finger The X ray beam is directed perpendicularly towards an imaginary line which bisects the angle between the sensor plane and the long axis of the tooth 2 1 Position the tu...

Page 20: ...ly Exposure time s Digital Sensor Adult Bitewing 5 8 0 4 Lower Molar 5 0 2 Upper Molar 30 0 32 Canine Maxilla 45 Mandible 20 0 25 Incisor Maxilla 45 Mandible 25 0 16 Child Bitewing 5 8 0 32 Lower Mola...

Page 21: ...30 0 25 Canine Maxilla 45 Mandible 20 0 13 Incisor Maxilla 45 Mandible 25 0 1 Film Adult Bitewing 5 8 0 8 Lower Molar 5 0 4 Upper Molar 30 0 63 Canine Maxilla 45 Mandible 20 0 5 Incisor Maxilla 45 Ma...

Page 22: ...Radiation Shielding Do not use cleaning agents other than ethanol since certain chemical combinations may deteriorate the HyperLight plastic prematurely 2 Unplug the charging cradle before cleaning NO...

Page 23: ...8 Maintenance Page 23 35 8 Maintenance If you do not use the machine for a long time you need to charge the machine every 6 months...

Page 24: ...nction Causes Methods Insufficient charge Use the charger to charge the machine The machine temperature is too high Let stand for more than half an hour Abnormal exposure time During the exposure proc...

Page 25: ...rent 2 5mA 20 Exposure time adjustment range 0 02 2S Nominal power 162 5W nominal at 65kV 2 5mA Inherent Filtration 0 8mmAl Total Filtration 1 8mmAl Duty Cycle 1 30 Minimum source to skin distance 20c...

Page 26: ...ical Data Page 26 35 Operating altitude 3000m above sea level Transport and storage conditions Ambient temperature 20 C 55 C Relative humidity 20 80 non condensing at 40 C Atmospheric pressure 70 kPa...

Page 27: ...minal tube voltage 70kV X ray source assembly maximum heat content 4500J Maximum anode cooling rate 110W Nominal anode input power 600W Target material Tungsten Minimum target angle 12 Filament voltag...

Page 28: ...10 Technical Data Page 28 35...

Page 29: ...network that supplies buildings used for domestic purposes Harmonic emissions IEC61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Complies Guidance and manufacturer s declaration...

Page 30: ...quality should be that of a typical commercial or hospital environment If the user of the HyperLight requires continued operation during power mains interruptions it is recommended that the HyperLigh...

Page 31: ...meters Field strengths from fixed transmitters as determined by an electromagnetic site survey should be less than the compliance levels V1 and E1 Interference may occur in the vicinity of equipment c...

Page 32: ...res may be necessary such as re orienting or relocating the Model 005 2 Over the frequency range 150 kHz to 80 MHz field strengths should be less than 1 V m 3 The ISM industrial scientific and medical...

Page 33: ...istance for the higher frequency range applies NOTE 2 The ISM industrial scientific and medical bands between 150 kHz and 80 MHz are 6 765 MHz to 6 795 MHz 13 553 MHz to 13 567 MHz 26 957 MHz to 27 28...

Page 34: ...tal Synthetic materials electrical components and printed circuit boards are disposed as electrical scrap Please deal with them according to the local environmental protection laws and regulation Righ...

Page 35: ...Changzhou Sifary Medical Technology Co Ltd Add NO 99 Qingyang Road Xuejia County Xinbei District Changzhou City 213000 Jiangsu P R China Tel 86 0519 85962691 Fax 86 0519 85962691 Email ivy sifary com...

Reviews: