14
Fastening by means of quick action bracing unit
In order to brace the drill rig by means of the quick action bracing unit, the distance
to the opposite wall must be between 1.7 m and 3 m.
Attention!
It is important that the drill rig is firmly connected to the surface. If not fixed
correctly, injuries to the operator or damages to the drilling unit may be
caused. Uncontrolled movements during drilling will cause the drill bit to hit
the surface to be drilled which may lead to a chipping of the segments. The
drill bit might also tilt in the bore hole which consequently will damage it.
I
Position the drill rig.
Place the quick-release column in the recess
behind the column on the stand foot (G).
The transport handle (H) must be turned
upwards in order to fasten it to the stand foot.
Loosen the fixing screws of the transport
handle using the turnstile and swivel the
handle forwards.
Fix the drill rig by turning the crank (L)
clockwise. Secure in position by means of
the appropriate bolt (K).
K
G
H