Installation
IMPORTANT:
A SmartLINK Gateway must be present and fully
operational in the dwelling.
IMPORTANT:
To install the Environmental Sensor, you must have
access to that Gateway in the SmartLINK app.
Location
The sensors can be installed in any room. However, some of the information
the sensors collect is room specific as detailed in the table below:
Ensure when installing the Environmental Sensors, that the location
selected is appropriate to the information sought.
The sensors are designed to be wall/ceiling mounted:
a. At approximately 1.4m from the floor level (for wall mounting)
b. At least 300mm from any walls or corners where there is dead air.
c. At least 300mm from any obstructions (eg. light fitting, decorative
object, furniture, curtains, etc...)
d. in free space.
Do
NOT
install:
a. Next to or directly above sources of Heat (such as cookers, heaters,
etc…).
b. Next to or directly above air conditioning vents, windows, wall
vents, etc…
c. In areas where it may be exposed to water splashes, dripping or
condensation (e.g. sink, above an electric kettle, etc…).
d. In direct sunlight.
Ei1020
Ei1025
Notes
Allergens Risks
Allergens Risks
Sensor must be
installed in Living Room
Cold Home Risk
Cold Home Risk
Sensor must be
installed in Living
Room or Bedroom
Damp & Mould Risk Damp & Mould Risk
Excess Heat Risk
Excess Heat Risk
Sensor must be
installed in Living
Room, Kitchen,
Hallway or Bedroom
Heat Loss Risk
Heat Loss Risk
Abandonment Risk
Indoor Air Quality
Risk
Ventilation Risk