EI Ei1020 Installation Manual Download Page 3

3

1.  Obstructions of any sort will result in a reduction in range from the free 

space specification. The range may vary depending on installation.

2.  Temperature and humidity conditions are for normal operation and 

storage. Units will function outside these ranges as required by the specific 

product Standards. Extended exposure to conditions outside these ranges 

can reduce product life. For advice on prolonged operation outside these 

ranges consult the manufacturer.

Technical Specification

Power supply

3V Lithium Battery (non-replaceable)

RF frequency

868.2MHz band (1% duty cycle)

RF Range

>100 Metres in free air

1

Receiver category

2

Typical RF power

8.1 dBm

Max RF power

+14 dBm

Data upload

Via the Ei1000G Gateway

Fixings

Supplied with screws, wall plugs and 
mounting bracket

Operating 
& Storage 
Temperature range

-10°C to 40°C

Operating & 
Storage Humidity 
range

15% to 95% Relative Humidity

2

 

(non-condensing)

Dimensions

70mm x 70mm x 34mm

Weight

Ei1020: 74g    Ei1025: 81g

Approvals

RF performance to EN 300 220-1 in 
accordance with EN 300 220-2
EMC performance to EN 301 489-1 in 
accordance with EN 301 489-3
Safety to EN 62368-1

Summary of Contents for Ei1020

Page 1: ...eing used It contains vital information on the installation of this product This manual should be regarded as part of the product Contents Page 1 Introduction 2 2 Product Overview 2 3 Technical Specif...

Page 2: ...umidity They are wireless and powered by a non replaceable lithium battery Any data collected by the sensors is uploaded via the SmartLINK Gateway to a portal where the information is displayed The En...

Page 3: ...cturer Technical Specification Power supply 3V Lithium Battery non replaceable RF frequency 868 2MHz band 1 duty cycle RF Range 100 Metres in free air1 Receiver category 2 Typical RF power 8 1 dBm Max...

Page 4: ...there is dead air c At least 300mm from any obstructions eg light fitting decorative object furniture curtains etc d in free space Do NOT install a Next to or directly above sources of Heat such as c...

Page 5: ...g care to avoid any electrical wiring drill holes using a 5 0mm drill bit through the centre of the marked locations Push the plastic screw anchors provided into the drilled holes Screw the mounting b...

Page 6: ...any defects that are due to faulty materials or workmanship This guarantee only applies to normal conditions of use and service and does not include damage resulting from accident neglect misuse unaut...

Page 7: ...d proper disposal please contact your local government of ce or the retailer where you purchased this product Block E1 0889 Hereby Ei Electronics declares that these Ei1020 Ei1025 Sensors are in compl...

Page 8: ...esbury Road Oswestry Shropshire SY10 8NR Telephone 01691 664100 www aico co uk Ei Electronics Shannon Industrial Estate Shannon V14 H020 Co Clare Ireland Telephone 353 0 61 471277 www eielectronics co...