background image

Instructions

Read and retain carefully for as long as the product is being used. It contains vital information on the operation 

and installation of your Module. The leaflet should be regarded as part of the product.
If you are just installing this Module, the leaftet must be given to the householder. The leaflet is to be given to 

any subsequent user.

EIB600MRF Module

(for use with EIB600 Series compatible Alarms only)

RadioLINK

+

 Module EIB600MRF

for Battery Powered Smoke / Heat Alarms
EIB600 Series

Summary of Contents for EIB600 Series

Page 1: ...f your Module The leaflet should be regarded as part of the product If you are just installing this Module the leaftet must be given to the householder The leaflet is to be given to any subsequent user EIB600MRF Module for use with EIB600 Series compatible Alarms only RadioLINK Module EIB600MRF for Battery Powered Smoke Heat Alarms EIB600 Series ...

Page 2: ...onal Features Indicator Summary System Examples Testing the system Interconnected Smoke Heat Alarms Carbon Monoxide Alarms RadioLINK Troubleshooting Technical Specifications Guarantee Limitations of Radio Communications Table of Contents 3 4 5 7 9 10 12 14 15 16 17 18 page ...

Page 3: ...ule attached to that Alarm will transmit an RF signal that will activate the sounders in all the other Alarms in the system The EIB600MRF module is plugged into the rear of the base of a Brooks compatible Alarm see Compatibility Table on page 4 RF communication through this module eliminates the need to install long interconnect wires between all the Alarms on different floors in different rooms T...

Page 4: ...fitted Intelligent Smoke Alarms EIB650iC EIB650iW Yes No Hardwired Interconnect Yes Yes Compatible with EIB600MRF Yes Yes Yes Yes Yes 1 RF Capability Model Heat Alarms Hardwired Interconnect Compatible with EIB600MRF 1 RF Capability EIB603TYC Standard Smoke Alarms Compatibility Table ...

Page 5: ...ight illuminates on the cover see Fig 2 Immediately release the button the blue light will flash rapidly and then stop Now attach the Alarm to its mounting plate see Installation section in the EIB650i Series booklet The flashing will repeat every 5 seconds thereafter Repeat this procedure for all RF devices in the system Check to ensure all RF devices have been successfully House Coded This can b...

Page 6: ... other RF devices in the system to exit House Code Alternatively the RF devices will automatically exit the House Code mode after 30 minutes Note Some RadioLINK devices do not support the on demand exit House Code feature You may allow them to automatically exit House Code after the time period or if you wish you can do it manually Consult the individual RadioLINK device manual for further instruc...

Page 7: ...wing features will only work with RadioLINK devices 1 Remote House Coding required if you want to add an Alarm to an installed system 2 Data Extraction Note these functions will not be available unless you have completed House Code Entry 1 Remote House Coding If it is necessary to extend an RF system or you find that you want to add an extra Alarm to a system you can now do so quite simply via the...

Page 8: ... N B for this feature to work all devices in the system must be RadioLINK 2 Data Extraction The EIB600MRF RadioLINK Module allows for the extraction of information from a Brooks Compatible Alarm using a Brooks download device Once the system has been set up information can be accessed securely from within or outside a property if access is an issue The event log can contain very useful information...

Page 9: ...s ReleaseonMulti ColourFlashing Rapid flashing followed by 3 5 Sec flash Off Off Off Power Up Blue LED Red LED Green LED Sounder Alarm Head Removal Full Sound NormalOperation Standby 1 flash 1 flash 3 5Secflashfollowedbyflashevery10Sec 3 5 Sec flash every 6 mins for 4 hrs Off Off Off Off 1 flash Off Off Off Off Off Off LowBattery EIB603TYC Low Battery EIB650iC iW Off Off Off Off Flash every 60 Sec...

Page 10: ...moke Alarm RadioLINK Heat Alarm RadioLINK Smoke Alarm RadioLINK Smoke Alarm Note Remote House Coding Monitoring Data Extraction only available on RadioLINK Alarms RadioLINK Smoke Alarm RadioLINK Heat Alarm RF Tool Data Extraction System Examples ...

Page 11: ...11 RadioLINK Smoke Alarm RadioLINK Heat Alarm RadioLINK Smoke Alarm RadioLINK Heat Alarm RadioLINK Smoke Alarm RF Tool Data Extraction RadioLINK System ...

Page 12: ...wered and that the circuit is functioning correctly To test the RadioLINK system press and hold the test button on one of the Alarms The blue LED from the EIB600MRF will illuminate for approximately 3 5 seconds Continue to hold the test button until all the Alarms in the system are sounding This will take a few seconds depending on the number of Alarms and their locations in the system e g a syste...

Page 13: ...e features of Brooks RadioLINK RadioLINK systems is that if there is a fault either in the Alarm itself or in the RF module fitted a beep will be transmitted around the system every 4 hours Depending on the Alarm type the beep may just be a short beep or it may be a 2 second alarm If your RF system is demonstrating this you have a fault either in 1 of your Alarms or in 1 of the RF modules fitted 1...

Page 14: ...entifying source of Alarm Brooks Smoke Heat Alarms and Carbon Monoxide Alarms can be interconnected via RadioLINK or RadioLINK so that one device sensing danger will cause all the other Alarms to sound When a system sounds check to see which device has its red light flashing rapidly this it the source of the alarm If it is a Smoke Heat Alarm evacuate the residence and follow the instructions in th...

Page 15: ...ot communicating and so shorten the path and or by pass an obstacle which is blocking the signal When the new Alarm is fitted House Code all Alarms again as described above ii rotate re locate the Alarms e g move them away from metal surfaces or wiring After making these changes to the RF signal path the RadioLINK signals may still not be reaching all the Alarms in your system even though they hav...

Page 16: ...RF Frequency 926MHz 1 duty cycle Dimensions 57mm length x 30mm depth x 18mm height Temperature Range 0 to 40 C Humidity Range 15 to 95 Relative Humidity non condensing Interconnect Up to 12 RadioLINK or RadioLINK modules Optional Accessories EIB407RF Manual Call Point EIB428RF Relay Module EIB450 RadioLINK Alarm Controller Approvals ACMA compliance to AS NZS 4268 2012 EMC performance to EN 301 489...

Page 17: ...is guarantee excludes incidental and consequential damage If this RF RadioLINK Module should become defective within the guarantee period it must be returned to Brooks with proof of purchase carefully packaged with the problem clearly stated We shall at our discretion repair or replace the faulty unit Do not interfere with the Alarm or attempt to tamper with it This will invalidate the guarantee b...

Page 18: ...blocked by radio signals occurring on or near their operating frequencies regardless of the House Coding ii Alarms with RadioLINK modules should be tested regularly at least monthly This is to determine whether there are sources of interference preventing communication that the radio paths have not been disrupted by moving furniture or renovations and if so to give a warning of these and other fau...

Page 19: ...osal will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product Block E1 ...