Instruction Manual

Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your 
Fire / CO Alarm Interface. The booklet should be regarded as part of the product.
If you are just installing the unit, the booklet must be given to the householder. The booklet is to be given to any subsequent user.

Model: Ei414

Fire / CO Alarm Interface

Summary of Contents for Ei414

Page 1: ...tal information on the operation and installation of your Fire CO Alarm Interface The booklet should be regarded as part of the product If you are just installing the unit the booklet must be given to the householder The booklet is to be given to any subsequent user Model Ei414 Fire CO Alarm Interface ...

Page 2: ...ams 2 Typical Installation Examples 3 Installation 4 House Coding 5 Testing 6 Service Relay 7 User Information 8 Troubleshooting the RadioLINK 9 Technical Specification 10 Service Guarantee 11 Contact Us 3 8 11 18 22 23 24 26 27 28 32 Page 2 ...

Page 3: ...s or alternatively can be used to trigger one of the other Systems RF transmitters A RadioLINK system consists of Ei Electronics RadioLINK Smoke Heat and CO Alarms along with RadioLINK accessory devices that are interconnected using the Ei Electronics proprietary RF protocol system The Ei414 must be House Coded to the other RadioLINK devices in the system service ON TEST OFF Fire CO Alarm Interfac...

Page 4: ...ents policy product performance and features are being frequently updated See Contact Us section The Alarms must be fitted on Ei168RC RadioLINK bases Ei605 Ei650 Series Smoke Alarms Alarms must be fitted with the correct Ei605 Ei650 series RadioLINK module Ei208W powered for life Carbon Monoxide Alarms The Alarms must be fitted with Ei200MRF RadioLINK modules Ei170RF other RadioLINK devices Contac...

Page 5: ...ction to External Panel see Manufacturers instructions Ei650RF Ei168RC Ei262 Ei450 RF Signal Input from Ei Alarm System Fire CO Alarm Controller service OFF 11 30VDC Ei208WRF Ei650RF Ei168RC Ei262 Ei450 RF Signal Input from Ei Alarm System Fire CO Alarm Controller External RF Panel Fire Telecare etc Wireless RF Connection Output Diagram RF Transmitter RF ...

Page 6: ...ion to External Panel RF Transmitter see Manufacturers instructions Ei650RF Ei168RC Ei262 Ei450 RF Signal Input from Ei Alarm System Fire CO Alarm Controller Ei208WRF Ei650RF Ei168RC Ei262 Ei450 RF Fire Signal Output Fire CO Alarm Controller External RF Panel Fire Telecare etc Wireless RF Connection Output Diagram External Device Strobe etc service External Fire Panel Input Connection Diagram RF T...

Page 7: ...nnection to External Devices see Manufacturers instructions Ei208WRF Ei650RF Ei168RC Ei262 Ei450 RF Fire Signal Output Fire CO Alarm Controller External Device Strobe etc Ei414 service ON TEST OFF Fire CO Alarm Interface External Fire Panel External Device sprinkler flow valve Input Connection Diagram 230VAC RF Transmitter RF Transmitter RF Transmitter ...

Page 8: ... CO Alarm Controller Ei450 Alarm Controller service ON TEST OFF Fire CO Alarm Interface External Panel Fire Telecare etc service ON TEST OFF External RF Panel Fire Telecare etc In the event of a fire the Ei161RC Ei166RC Ei164RC will detect Smoke Heat and the Ei168RC base will transmit an RF fire signal to the Ei414 The Ei414 will then trigger the external panel N B The Ei450 Alarm Controller MUST ...

Page 9: ...troller Fire CO Alarm Controller Ei450 Alarm Controller Fire CO Alarm Controller Ei450 Alarm Controller service ON TEST OFF Fire CO Alarm Interface fire CO service ON TEST OFF Fire CO Alarm Interface External Panel Fire Telecare etc Ei414 service ON TEST OFF Fire CO Alarm Interface External RF Panel Fire Telecare etc External RF Panel Fire Telecare etc In the event of a fire the Ei650RF Ei603TYCRF...

Page 10: ...arm Controller Fire CO Alarm Controller Ei450 Alarm Controller RF Transmitters Ei414 fire CO service ON TEST OFF Fire CO Alarm Interface Ei414 service ON TEST OFF Fire CO Alarm Interface External RF Panel Fire Telecare etc External RF Panel Fire Telecare etc In the event of a fire CO event the relevant Smoke Heat CO Alarm will transmit an RF signal to the Ei414 The Ei414 will then trigger the rele...

Page 11: ...Antenna Battery Backup Switch RadioLINK LED Service Relay CO Relay Screw Fixings Screw Fixings Voltage Input 12 24V AC Mains Input 230V Volt Free Contacts DC Power In 11 30V Trigger inputs to send fir signal to the RF Alarm system These inputs wil also activate fire relay Power inputs 11 3 Installation ...

Page 12: ...xings Battery Backup Switch Screw Fixings Voltage Input 12 24V AC Mains Input 230V Volt Free Contacts DC Power In 11 30V Trigger inputs to send fire signal to the RF Alarm system These inputs will also activate fire relay Power inputs Note This MUST be switched to the ON position upon installation see Installation section N B The Lithium battery is not replaceable 12 ...

Page 13: ... Disconnect the AC mains supply from the circuit that is going to be used The disconnect device i e mains switch must be an all pole circuit breaker with a contact gap of minimum 3mm and disconnects both poles simultaneously 3 The house wiring must be connected to the terminal block on the unit L Live connect to the house wires coloured brown or marked L N Neutral connect to the house wires colour...

Page 14: ...ckout segments on the back of the base Remove segments using a pliers or similar See diagrams on page 15 8 Fit and secure the top cover with the screws provided see page 3 9 Insert and turn the key supplied to the TEST position to begin system testing see TESTING section For a 11 30V DC external source 1 The Ei414 should be located next to DC external source 2 Locate the auxiliary power output in ...

Page 15: ...olar panel the Total Harmonic Distortion THD must be less than 5 If in doubt please check with the manufacturer of the inverter This also applies to battery powered UPS Uninterruptible Power Supply inverters or Light Dimmer Circuits The Ei414 must not be connected when the house wiring insulation is being checked with high voltages i e do not use a high voltage insulation tester on the unit The un...

Page 16: ...2 1 2 O N O N O N O N Switch 1 1 2 1 2 1 2 1 2 2 1 2 1 2 1 2 O N O N O N O N Switch 1 1 2 1 2 1 2 1 2 2 1 2 1 2 1 2 Normal operation mode default continuous operation no delay Switch 1 2 in the 1 2 position Pulsed Operation Relay fires for 4 seconds no delay Switch 1 2 in the ON position 10 Sec delay Relays fire 10 secs after it receives message If a cancel message is received within this period t...

Page 17: ... fire alarm signal activates the fire relay or to a CO alarm signal activates the CO relay It will not respond to a button test signal In the TEST position the Ei414 responds to a button test signal will activate the fire or the CO relay depending on the unit that was button tested N B When testing the system with an Ei450 Alarm Controller only the fire relay will activate Keyswitch Orientations ...

Page 18: ...l screwdriver press and hold the House Code button on the bottom of the Ei414 then release The RadioLINK blue LED will light up and then flash rapidly for a moment House Code all other RadioLINK Alarms and devices in the system Consult the instruction manuals on how to House Code the Alarms and devices It is essential that each individual Alarm device is put into House Code mode in it s actual loc...

Page 19: ...are seen The flash pattern will repeat every 5 to 10 seconds while the Ei414 remains in House Code If it fails to flash the correct number of times then consult the Troubleshooting section of this instruction manual Now walk around the house to verify that all the other RadioLINK Alarms and devices are giving the correct amount of flashes If any of these fail to flash the correct number of times t...

Page 20: ...ess the House Code button on the Ei414 When the RadioLINK LED lights up blue release the button This unit will then send an exit House Code signal to all the other RadioLINK Alarms and devices to exit House Code After a short period the blue light will turn off and the system will return to standby mode normal Depending on the number of RadioLINK Alarms and devices in the system this period could ...

Page 21: ...again To reset the Ei414 press and hold the House Code button The RadioLINK LED will flash blue briefly and then go solid After 5 seconds approx the blue LED will start flashing slowly At this point release the House Code button The Ei414 has now been reset To reset the other RadioLINK Alarms and devices in the system consult the appropriate instruction manuals Reset the House Code ...

Page 22: ...mode the entire system can be tested Relay activation can be confirmed by the flashing of the relevant LED on the front over 1 Button test each Smoke Heat Alarm in the system this will activate the fire relay Similarily button test each CO Alarm in the system this will activate the CO relay The person responsible for testing the system MUST notify the Alarm Receiving Center or equivalent that an A...

Page 23: ...in order to detect the source of the issue In the instance where an Alarm head has been removed please replace it If there is a Sensor Fault or Low Battery indication Please consult individual Alarm manual for fault indicators the Alarm must be replaced Reset Service Relay The Service relay can be reset in two different ways 1 Identifying and fixing the appropriate issue as indicated in the sectio...

Page 24: ... Ei450 Alarm Controller Frequent testing of the Fire CO Alarm system is advised to ensure its continued and safe operation Guidelines and best practices for testing are as follows 1 After the system is installed 2 Once weekly thereafter 3 After prolonged absence from the dwelling e g after holiday period 4 After repair or servicing of any of the system s elements or household electrical works Plea...

Page 25: ... basic responses in the instance of a fire or CO event If there is a fire immediately evacuate the premises and telephone the fire brigade If a CO Alarm has sounded open all doors and windows while evacuating the premises Contact the appropriate authorities to report the incident The Ei450 Controller is a useful device in that it will indicate whether there is a fire CO event taking place The rele...

Page 26: ...g the Alarms or relocating the Alarms e g move them away from metal surfaces or wiring as this can significantly improve signal reception Rotating and or relocating the Alarms may move them out of the range of existing units even though they may have already been House Coded correctly in the system It is therefore important to check that all Alarms are communicating in their final installed positi...

Page 27: ...t for Fire marked Red light for CO marked Service Indicator Red light marked RF Frequency 868 499 MHz Mounting Can be easily mounted onto a wall Guarantee 5 Years Outputs Fire Alarm Relay NO NC CO Alarm Relay NO NC Service Alarm Relay NO NC Relay Contacts All relays are rated 250VAC 5 Amp Resistive Operating Temp 0 40oC Storage Temp 0oC 35oC dry area Humidity Range 15 to 95 Relative Humidity non c...

Page 28: ... service and does not include damage resulting from accident neglect misuse unauthorised dismantling or contamination howsoever caused This guarantee excludes incidental and consequential damage If this device should become defective within the guarantee period it must be returned to Ei Electronics with proof of purchase carefully packaged with the problem clearly stated We shall at our discretion...

Page 29: ...ares that this Ei414 Fire CO Alarm Interface is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The Declaration of Conformity may be consulted at www eielectronics com compliance 29 ...

Page 30: ...l will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product Block E1 30 ...

Page 31: ...31 ...

Page 32: ... Road Oswestry Shropshire SY10 8NN U K Telephone 01691 664100 www aico co uk Ei Electronics Shannon Industrial Estate Shannon Co Clare Ireland Telephone 353 0 61 471277 www eielectronics com 11 Contact Us P N B18063 Rev 1 Ei Electronics 2015 ...