Ei3105RF DataSht RevB

 

Model 

Ei3105RF Optical 

 

RF wireless interconnect  

 

Unique house coding feature 

 

Visual RF transmission indicator 

 

High performance optical chamber with integral 
insect screen 

 

Test button 

 

Advanced suppression and calibration technology 

 

Radio transmitter and receiver in each alarm 

 

Built in auto self test feature 

 

Low power cell warning 

 

Kitemarked to BS EN 14604:2005 

 

5 year guarantee 

 
 

Product Description 

 

The Ei3105RF is an Optical Smoke Alarm that runs on 
9V alkaline battery and is part of the Radio Frequency 
range of smoke alarms.  The RF signal will wirelessly 
interconnect the Ei3105RF to other RadioLINK products  

 

The Ei3105RF uses advanced radio transceiver 
technology with unique software coding to transmit and 
receive the radio signals.  The transmissions are 
frequency modulated (FM) and use Manchester coding 
to ensure robust signal integrity and avoid signal noise 
interference 
 
The Ei3105RF has other advanced features such as high 
performance optical chambers fitted with integral insect 
screens to reduce the chances of false alarms, as well 
as the ability to wireless interconnect up to twelve alarms 
to allow all alarms to sound if just one of the 
interconnected alarms should be triggered. 
 
The Ei3105RF has built in circuitry to aid suppression of 
voltage transients and RF interference to further reduce 
the chances of false alarms under such conditions 
 
 
 

 

Operation 

 

 

The red indicator will flash every 40 seconds to show that 
the detector has performed an automatic self test 

 

 

In normal standby mode the amber indicator will light to 
indicate transmission of an RF signal 

 

 

In code mode, the amber indicator will flash to indicate the 
number of other RF alarms that have been “learned” in the 
system 

 

 

The red indicator will flash rapidly to show an alarm 
condition for the smoke detector 

 

 

The “Test/Hush” button will either silence false alarms or 
perform a unit self test 

 

 

In “Hush” mode the alarm enters a ten minute period of 
reduced sensitivity and the red light flashes every 10 
seconds and then resets 

 

 

When interconnected to other Ei mains powered alarms, an 
alarm on one detector will trigger all other interconnected 
alarms within one second (only the triggered alarm will flash 
a red indicator) 

 

 

The smoke detector will emit a beep and the red light 
flashes every 40 seconds to indicate that the battery is 
depleted and needs to be changed 

 
 