for dwellings where occupants may be at high risk (e.g. elderly)
OPTIMUM PROTECTION
LD1
Optimum Protection LD1:
As LD2, but in addition
alarms should be located in all rooms and other areas
of the dwelling. (apart from toilets or bathrooms)
Multi Storey Dwelling LD1
Living
Room
Bedroom
Bathroom
Kitchen
Bedroom
Shower
Garage
Bedroom
Bedroom
Bedroom
Kitchen / Dining Room
Living Room
Bathroom
Single Storey Dwelling LD1
Heat Alarm
do not fit alarm
Multi-Sensor Fire Alarm
Heat Alarms
located in:
(Heat Alarms must be within 5.3m of potential fire
sources)
each kitchen
garages
Multi-Sensor Fire Alarms or Heat Alarms
located in:
each Living room (i.e. most frequently used
daytime room)
Multi-Sensor Fire Alarms
located:
on each storey
every 7.5 m of hallways and escape routes
within 3m of all bedroom doors
in all other rooms & areas other than listed below
(apart from toilets & bathrooms )