Ei Electronics Ei 105B User Instructions Download Page 11

Do not overload electrical circuits.

Keep matches away from children.

Never smoke in bed. In rooms where you do smoke, always
check under cushions for smoldering cigarettes and ashes.

Service central heating systems regularly.

Be sure all electrical appliances and tools have a recognised
approval label.

This device cannot protect all persons at all times. It may not
protect against the three most common causes of fatal fires:

1. Smoking in bed.

2. Leaving children at home alone.

3. Cleaning with flammable liquids, such as petrol.

Further information can be obtained from the Home Office
Publication entitled “Smoke Detectors in the Home” (FB2) or
from your local fire prevention officer.

What is the best Smoke Alarm - Optical

or Ionisaton ?

Both types respond in all standard fires but each type may
respond faster to particular fires as shown. Ei Electronics
manufactures two complementary 10 Year Smoke Alarms ,
Optical Smoke Alarm Ei3105C and Ionisation Smoke Alarm
Ei100TYC with built-in Lithium battery. For 

dual

protection

install each type.

The Home Office states (in FB2):

“If your home has more than one floor , at least one alarm
should be fitted on each level. In this case a combination of
Optical and Ionisation alarms, preferably interconnected, will
give the best protection.”

Getting your Smoke Alarm Serviced

If your Smoke Alarm fails to work after you have read the
sections on “Connecting the battery” and “Looking after your
Smoke Alarm” contact Customer Assistance at the nearest
address given at the end of this leaflet. If it needs to be returned
for repair or replacement put it in a padded box (battery

12

B10274-R4-105B-U&C-ENG  30/9/09  8:23 AM  Page 11

Summary of Contents for Ei 105B

Page 1: ... your home so it can wake you and your family in time for you all to escape A single Smoke Alarm will give some protection if it is properly installed but most homes will require two or more to ensure that a reliable early warning is given For maximum protection you should put individual Smoke Alarms in all the rooms where fire is most likely to break out Your first Smoke Alarm should be located b...

Page 2: ...3 B10274 R4 105B U C ENG 30 9 09 8 23 AM Page 2 ...

Page 3: ...ng in the room such as an elderly or sick person or a very young child d Checking you can hear your Smoke Alarm With the Smoke Alarm sounding in its intended location check you are able to hear it in each bedroom with the door closed above the sound of your radio The radio should be set to a reasonably loud conversation level If you can t hear it over your radio the chances are that it wouldn t wa...

Page 4: ...ight stop smoke from reaching the unit Next to or directly above heaters or air conditioning vents windows wall vents etc that can change the direction of airflow In very high or awkward areas where it may be difficult to reach the alarm for testing battery replacement etc Locate unit at least 1 5m 5 feet and route wiring at least 1m 3 feet away from fluorescent light fittings as electricial noise...

Page 5: ...to Ceiling or Wall NB For Interconnecting see page 9 The Smoke Alarm is battery operated and needs only wiring if the Inter Link facility is being used 1 Pull cover open at tab Remove cover from base by separating at rear snap in hinges by rotating cover backwards 2 Place the base on ceiling or wall exactly where you want to mount the unit With a pencil mark the location of the screw holes 3 Takin...

Page 6: ...rp when attaching the Battery Connectors to the Battery Battery Missing indicator Some models are fitted with a warning flag which pops up when the battery is removed This prevents the cover from closing when there is no battery in the unit When the battery is being installed or changed this flag must be held down while gently pushing the Battery into the Battery Holder Figure 7 a Looking after yo...

Page 7: ... can set fire to the alarm and damage the house We do not recommend testing with smoke as the results can be misleading unless special apparatus is used c Replacing the Battery A fresh Battery should last about one year When Battery power is low and replacement is necessary the Alarm will beep and the LED will flash at the same time about once per minute for at least 30 days The battery must then ...

Page 8: ...gure 9 before screwing to ceiling Draughts from wiring openings conduit or mounting boxes holes may blow smoke away from the sensing chamber making it insensitive It is essential that all such openings be closed by silicone sealant or similar After wiring together the Interconnect Smoke Alarms test the first unit by pressing the button All the detectors should alarm and the test button on the firs...

Page 9: ...s for this Smoke Alarms will not work if the batteries are depleted or if they are not connected or if the wrong type of battery is used Test regularly and replace batteries at least yearly or when depleted Smoke Alarms will not detect fire if sufficient smoke does not reach the alarm Smoke may be prevented from reaching the Alarm if the fire is too far away for example if the fire is on another f...

Page 10: ...oors behind you as you leave 2 If smoke is heavy crawl out staying close to floor Take short breaths if possible through a wet cloth or hold your breath More people die from smoke inhalation than from flames 3 Get out as fast as you can Do not stop for packing Have a prearranged meeting place outside for all family members Check everybody is there 4 Call the Fire Brigade from a neighbour s house R...

Page 11: ...aton Both types respond in all standard fires but each type may respond faster to particular fires as shown Ei Electronics manufactures two complementary 10 Year Smoke Alarms Optical Smoke Alarm Ei3105C and Ionisation Smoke Alarm Ei100TYC with built in Lithium battery For dual protection install each type The Home Office states in FB2 If your home has more than one floor at least one alarm should ...

Page 12: ...se false alarms The latest design materials and manufacturing techniques have been used in the construction of our Alarms to minimize the effects of contamination However it is impossible to completely eliminate the effect of dust and insect contamination and therefore to prolong the life of the Smoke Alarm you must ensure that it is kept clean so that excess dust does not build up Any insects or ...

Page 13: ...European Standard EN14604 2005 MODEL TYPE The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream Proper disposal will prevent possible harm to the environment or to human health When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environment...

Page 14: ...moke alarm must be removed or covered fully with a plastic bag or similar before renovations begin Contains vital information on unit operation and installation Read and retain carefully If you are just installing this unit this leaflet MUST be given to the householder Please read the first short section containing basic information SMOKE ALARM OPTICAL Models Ei105B Ei105C WITH INTERCONNECT Ei Ele...