![EHRET FSL-light Installation Instructions Manual Download Page 17](http://html1.mh-extra.com/html/ehret/fsl-light/fsl-light_installation-instructions-manual_2368726017.webp)
17
2 Installation instructions
position the hinge sash under the guide rail
and align it using a spirit level.
2.12
View from outside
check the gap (7 mm) between the hinge
sash and the guide rail.
Hang the brackets on the hinge and screw
onto the base.
2.13
48
5
50
7
8 mm projection
Guide rail
edge of
window
frame
brackets
Hinge sash
Hinge inst
allation
height
check the sash again using a spirit level.
Fasten the lower hinge.
Hang the access sash and carry out a shut-
ting test.
Shutting test:
Both sashes must be parallel
to the façade when closed!