background image

www.ehcteknik.com

Assembly Instruction

EHC HT10    

Page  1

Hauptsitz

Schweden

Benelux

Deutschland

England

EHC Teknik ab

EHC Teknik bvba

EHC Teknik GmbH

EHC Teknik Ltd

Ögärdesvägen 8a

Karel Soetelaan 37

Eiserfelder Str.316

10 Hollow Rise

S

433 30 Partille

B-2150 Borsbeek

D-57080 Siegen

High Wycombe

Tel.: +46 (0)31 449020

Tel.: +32(0)3 3663936

Tel.: +49 (0)271 3177936

Bucks HP13 5NU

Fax.:+46 (0)31 444980

Fax .:+32 (0)3 3662633

Fax .:+49(0)271 3177937

Tel.: +44(0)1494 445503

E

Mail, [email protected]

E

Mail, [email protected]

E

Mail, [email protected]

Fax .:+44 (0)1494 442242

www.ehcteknik.com

www.ehcteknik.be

www.ehcteknik.de

E

Mail. [email protected]

www.ehcteknik.nl

www.ehcteknik.co.uk

www.ehcteknik.fr

Page  1

Summary of Contents for HT10

Page 1: ...rtille B 2150 Borsbeek D 57080 Siegen High Wycombe Tel 46 0 31 449020 Tel 32 0 3 3663936 Tel 49 0 271 3177936 Bucks HP13 5NU Fax 46 0 31 444980 Fax 32 0 3 3662633 Fax 49 0 271 3177937 Tel 44 0 1494 445503 E Mail office ehcteknik se E Mail ehc teknik skynet be E Mail buero ehcteknik de Fax 44 0 1494 442242 www ehcteknik com www ehcteknik be www ehcteknik de E Mail sales ehcteknik net www ehcteknik ...

Page 2: ... 3 Page 2 Mounting 1 The unit is mounted using the two clamping rings 1 to the intended machine 2 The lowest point determines the hole for the outlet of the condensate 2 3 Companion flange 3 appropriate to the size of the vehicle For the measurements of the filter unit and connections see technical data 2 Important Mount the unit with condensate hose 2 as the lowest point Important Mount the devic...

Page 3: ...ail pipe using the second flange ensuring that the outlet hole is no smaller than the I D of the machine tailpipe Warning Do not use the second flange to blank off the outlet if no tailpipe is required Filter replacement 1 Page 3 1 Loosen eccentric locks 1 on the filter housing 2 Remove the filter container 2 3 Remove the filter element 3 from the filter container 2 and insert the new filter cartr...

Page 4: ...ing device according to IP54 1 Delay relay 2min 2 Buzzer 3 Lamp 4 P it h 4 2 3 1 Important Beware of not breaking the moisture blocking seal ing on the guard at the Important Mount the delay relay protected in the cabin IP54 5 Page 4 4 Pressure switch 5 Fuse 2A Mechanical pressure guard Optional The mechanical pressure guard 1 vents when filter replacement is necessary Replace the membrane of the ...

Page 5: ...m temperature exhaust 250 C K Value recommended 1 3 Weight 23kg Life expectancy depends on engine size engine type the engine used and engine condition EHC HT Filter meet the exhaust requirements TÜV Fahrzeug GmbH S 129 99 001 00 TRGS 554 D VERT Filter List B135 10 03 CH COSHH GB 2 3 4 Page 5 1 2 Page 5 ...