EHC
Fusion E10 Combi
–
Installation and technical manual
Page 27
15.
Commissioning: Fusion boiler instructions/Cont.____
Front Control Panel
Indicator B
When GREEN light is on the pump is operating. When this light flashes the flow rate
is insufficient (less than 5 ltr per min) Refer to technical specifications
Indicator C
When light is off room thermostat temperature has been achieved. (RP is open)
When the green light flashes the NA connection is open. (na should always have link
installed)
When RED light is on, the boiler is operating
When GREEN light is on boiler temperature has been achieved.
Indicator F
Set Temperature
Indicator D
Return Temperature
When this indicator flashes the return temperature sensor is faulty.
Indicator E
Flow Temperature
When this indicator flashes the flow temperature sensor is faulty.
Indicator G
Press to show Flow, Return and Set Temperature
Indicator H
Press to check flow rate
Indicator I
Press to check power consumption
Indicator A
DHWC Indicator