SSR
Operating Instructions
8/10
Vers.2.3
© ehb errors expected
Bedienungsanleitung.doc
•
Assembly
-
Assembly is visible in the engine compartment
-
Use short cables from the ignition start switch and to the starter
-
Protect the SSR from exposure to water and dirt
-
Assemble in a low-vibration location
-
Assemble with the connector side facing downwards
-
Provide sufficient spacing for the connector and cables
Hardware
-
Load capacity switch output terminal 50f:
25 A (static)
-
Short circuit current limit terminal 50f: 65 – 180 A
-
Rated voltage of devices: 12 – 24 V
-
Working voltage range: 9 – 36 V
-
Output D+: max. 2 A permanent (option only)
-
Protection against permanent reverse polarity of the supply voltage
-
No current flow at the outputs in case of reverse polarity of the supply voltage
-
Functional range –40 to +85 °C
-
Base body and housing material:
Relay housing with moulded lugs
Dimensions: 60 x 30 x 60 mm; material: PA6.6
Base plate; material: PA6. 6 + 30% FV;
number of contacts: 8
-
Colour:
Black
-
Protection class according to
DIN 40050 sheet 9:
When using a multiple plug connector
Terminals IP 20
Housing IP 53
Connector must be pointing downwards