General Information 

 

1.1  Target Group 

This documentation is intended for technical service personnel. 
 
 

1.2  Important Information for Use 

Use

 

The device may only be operated with the accessories supplied. 
Clean the device with mild cleaning agents only. 
Do not insert any objects which were not designed for this specific purpose into the 
openings of the device, as this may lead to faults in the electronics. 

When operating the device, always observe the general  

accident prevention regulations.

 

 

Safety

 

Do not operate the 

SSR

 within range of strong electromagnetic fields. 

Please observe the temperature specifications!  
 

Storage

 

When not in use, the 

SSR

 device may only be stored according to the operating 

specifications. 

Installation 

During the installation of the device follow the directions of the manufacturers of 
plugs and wire harnesses. 

Shipping

 

The device may only be shipped in its original packaging or in equally sturdy 
packaging.  
Use of unsuitable packaging constitutes 

negligence, 

whereby any repair under  

warranty is forfeited.  
 

Maintenance

 

The SSR requires no maintenance throughout its entire service life and requires 
 no special care. 
 

Opening the 

SSR

 

The SSR contains no parts that can be maintained, replaced or repaired by the 
customer or anyone other than authorised ehb maintenance staff. 
 
 

 

1.3  Device Repair

 

  

Should a repair be necessary, please send the device to: 

ehb electronics gmbh 

Hans-Böckler-Str. 20 

30851 Langenhagen, Germany 

Please ensure that you enclose a written description of the fault(s). This will make it much easier for 
the ehb electronics gmbh service department to find the error and return the 

SSR

 to you quickly. 

Alternatively, use our online service for returning the device: 

www.ehbservice.de

 

 
 

Summary of Contents for ehb5040 Series

Page 1: ...040x Version 2 3 It is not permitted to pass on or copy this documentation or to use or disclose its content unless expressly approved We reserve the right to recover damages for any contraventions All rights are reserved in the case of patent issue or utility model registration ...

Page 2: ...vice Repair 3 1 4 Product Disposal 4 Component Description Function 5 2 1 The following conditions prevent the start up process 5 2 2 The following conditions interrupt the start up process 5 2 3 Scope of Protection 5 2 4 Safety Concept 5 Assembly 6 Hardware 6 Technical Documentation 7 Housing Dimensions 8 Connection Diagram 9 Wiring Diagram 9 Document Information History 10 Imprint 10 ...

Page 3: ...During the installation of the device follow the directions of the manufacturers of plugs and wire harnesses Shipping The device may only be shipped in its original packaging or in equally sturdy packaging Use of unsuitable packaging constitutes negligence whereby any repair under warranty is forfeited Maintenance The SSR requires no maintenance throughout its entire service life and requires no s...

Page 4: ... applicable statutory provisions Batteries As the end user you are legally obliged pursuant to the German Battery Directive BattV to return all used batteries after use Batteries may not be disposed of in household waste Batteries that contain harmful substances are marked with the symbol shown which indicates that it is prohibited for them to be disposed of in household waste The designations for...

Page 5: ...vent the start up process There is already voltage present at input terminal W After each start attempt the ignition must be switched off for at least two seconds After 6 seconds a new start is possible 2 2 The following conditions interrupt the start up process The frequency at terminal W exceeds a specified value 2 3 Scope of Protection Start inhibited while the engine is running Start inhibited...

Page 6: ...tatic Short circuit current limit terminal 50f 65 180 A Rated voltage of devices 12 24 V Working voltage range 9 36 V Output D max 2 A permanent option only Protection against permanent reverse polarity of the supply voltage No current flow at the outputs in case of reverse polarity of the supply voltage Functional range 40 to 85 C Base body and housing material Relay housing with moulded lugs Dim...

Page 7: ...requency electromagnetic fields according to IEC 1000 4 3 EN 61000 4 3 VDE 0847 part 4 3 2003 11 Interference immunity to transient disturbance variables bursts according to IEC 1000 4 4 EN 61000 4 4 VDE 0847 part 4 4 2002 07 Interference immunity to impulse voltages surges according to IEC 1000 4 5 EN 61000 4 5 VDE 0847 part 4 5 2001 12 Interference immunity to conducted interference induced by h...

Page 8: ...enungsanleitung doc Housing Dimensions Relay housing with moulded lugs dimensions 60 x 30 x 60 mm material PA6 6 31 W 15 50f 50e D 30 95 5 mm 40 7 mm 59 9 mm 61 0 mm 35 4 mm 31 0 mm 60 0 mm 38 2 mm 6 4 mm 82 3 mm 8 3 mm 20 0 mm 24 0 mm 61 0 mm 5 7 mm 25 7 mm 71 0 mm ...

Page 9: ...SSR Operating Instructions 9 10 Vers 2 3 ehb errors excepted Connection Diagram WiringDiagram ...

Page 10: ...out adjustment 25 08 2011 O Howind 2 1 Technical documentation amended 04 10 2011 O Howind 2 1 Formatting 18 10 2011 Hag 2 1 Error correction 05 01 2012 How Sch 2 1 Layout adjustment 13 08 2014 Hag 2 2 Adaptation 01 02 2017 Hag 2 3 Adaption Information to use 14 01 2019 Hk Hag Imprint Customer service Tel 49 511 123207 0 Fax 49 511 123207 77 Email info ehb electronics de Hans Böckler Str 20 30851 ...

Reviews: