11
Configuring Port Parameters
Use the Port Configuration menu to display or set communication parameters for any port on the
switch, including link status, administrative status, auto-negotiation, communication speed and
duplex mode, as well as flow control in use.
Smart Switch: Port Configuration
================================
Port Link Admin Type Current Flow Flow Control
Status Status Config Type Control Status
---------------------------------------------------------------------
01. Off Disabled 100TX-HDX 100TX-HDX Off Off
02. Off Enabled 10HDX 10HDX Off Off
03. Off Enabled 1GB-FDX 1GB-FDX Off Off
04. Off Enabled Auto-Nego 10HDX Off Off
05. Off Enabled Auto-Nego 10HDX Off Off
06. Off Enabled Auto-Nego 10HDX Off Off
07. Off Enabled Auto-Nego 10HDX Off Off
08. Off Enabled Auto-Nego 10HDX Off Off
< Return >
Use arrow keys to move. <Space> to make change.
Menu
Default
Description
Link Status
Indicates if the port has a valid connection to an external device.
Admin Status
Enabled
Allows you to disable a port due to abnormal behavior (e.g., excessive
collisions), and then re-enable it after the problem has been resolved.
You may also disable a port for security reasons.
Type Config
Auto-Nego Enables auto-negotiation for speed and duplex mode or manually sets
these parameters. The manual settings available are:
10HDX:
10 Mbps, half duplex
10FDX:
10 Mbps, full duplex
100TX-HDX:
100 Mbps, half duplex
100TX-FDX:
100 Mbps, full duplex
1GB FDX:
1 Gbps, full duplex
Current Type
Indicates the current speed and duplex mode.
Flow Control
Off
Used to enable or disable flow control. Flow control can eliminate frame
loss by “blocking” traffic from end stations or segments connected
directly to the switch when its buffers fill. When enabled, back pressure
is used for half duplex, and IEEE 802.3x for full duplex. Note that flow
control should not be used if a port is connected to a hub. The options
for flow control are set out below:
Switch Link
Partner
Flow
Control
Rcv/BothWay SendOnly
Switch can only receive pause frames,
link partner can only send pause
frames.
Rcv/BothWay BothWay
Both switch and link partner can
send and receive pause frames.
Flow Control
Status
Displays current flow control status.