![Ega Master 57542 Operating Instructions Manual Download Page 24](http://html1.mh-extra.com/html/ega-master/57542/57542_operating-instructions-manual_2367627024.webp)
24
RESETTING THE WRENCH
- Press
together will reset the wrench.
- If the wrench does not function normally,
Press
together to reset the wrench.
LOW BATTERY VOLTAGE PROTECTION
If the battery serial voltage is in low voltage status, the wrench will display a battery symbol
and then turn off after a while.
WHEN CHANGING THE TYPE OF HEAD
- If you use the different head of the wrench, the reading on the display will be different for the
different length of the head. Please refer to the following explanation.
Calibration Point
D : The set torque
D1: The actual torque applied to the nut.
L1: The extended length
L2: The normal length
L3: The length from the fitting pin to the calibration point.
- Reference dimension for each model:
Model
L2(mm)
L3(mm)
57585-57589
29
272.7
57586-57590
29
287.7
57588
29
287.7
57587-57591
40
381.2
57592
40
501.2