NOTE

: Do not exceed 24 VDC at the input of the EZ-3u controller. Doing so may cause the on-

board regulator to overhead and shut-down, preventing operation of the controller. When in doubt, 
use a regulated power supply.

EZ-3micro Connections & Controls

A.

Power input: 2.1mm barrel jack; 12 to 24 VDC

K.

OFF time potentiometer

B.

Power input pads: 12 to 24 VDC

L.

High-current pulse output (valve, relay, etc.)

C.

Power switch (OFF / Configure / Run)

M.

Open-collector/5V pulse output (audio player)

D.

Switched power output

N.

OC/5V configuration jumper

E.

Start input: dry contact

O

Normally-closed relay output

F.

Start input: 12 to 24 VDC

P.

Normally-open relay output

G.

Start input: PIR 

Q.

Pot configuration jumper

H

Start input: manual button

R.

Programming header (for hackers; see note)

I.

PRE delay potentiometer

J.

RUN time potentiometer

NOTE

: While a programming header is provided for advanced users interested in hacking the 

EZ-3u for their own purposes, EFX-TEK provides no support for hacking beyond a schematic for 
the product. Schematic is available from 

www.efx-tek.com

.

Power Input

The EZ-3u is powered from 12 to 24 volts DC.  DC power may be connected to via the 2.1mm power jack (A) 
or through the V+ and GND pads (B) located just above the power jack. When the power switch (C) is in  
position 2 (Run) the input power is routed to the V+ and GND output terminal block (D); this can be useful for  
providing power to the relay contacts or sharing power with other devices (e.g., audio controller).