- AB620A5035
Instruction Manual
- 83 -
11.2 Technical level
(Code no. 1907)
Parameters Designation
Unit
Max
Min
Preset
Ind.
100
SSc Number of softstart stitches
Stitches
254
0
2
101
EvA Switch-on start backtack for the backtacking solenoid in
the initial backtack
ms
255
0
43
102
AvA Power-off start backtack for the backtacking solenoid in
the initial backtack
ms
255
0
4
103
EvE Switch-on start backtack for the backtacking solenoid in
the final backtack
ms
255
0
43
104
AvE Power-off start backtack for the backtacking solenoid in
the final backtack
ms
255
0
5
108
PEr Stop position of the ornamental backtack
1 = Position 1 leading
2 = Position 2 leading
3 = Position 1 trailing
4 = Position 2 trailing
5 = Position 3 leading
6 = Position 3 trailing
6
1
1
109
n13 Speed of manual backtack
RPM
9900
200
1500
110
n1 Positioning speed for threading (mode 66)
RPM
390
70
200
111
n2 Upper limit setting range of the maximum speed
RPM
9900
n2_
5000
112
n3 Start backtacking speed
RPM
9900
200
1200
113
n4 End backtacking speed
RPM
9900
200
1200
114
n5 Speed after light barrier sensing
RPM
9900
200
1200
115
n6 Softstart speed
RPM
9900
70
500
116
n7 Trimming speed
RPM
700
70
200
117
n10 High lift for walking speed limitation
RPM
9900
400
1000
118
n12 Automatic speed for stitch counting
RPM
9900
400
3500
119
nSt Speed stage graduation
1 = Linear
2 = Slightly progressive
3 = Highly progressive
3
1
121
n2 Lower limit setting range of the maximum speed
RPM
n2_
200
400
122
n9 Limited speed n9
RPM
9900
200
2000
123
n11 Limited speed n11
RPM
9900
200
2500
125
bot
Speed limitation using ext. potentiometer (minimum value)
RPM
Pa.25 0
200
126
Pot
Function “speed limitation using external potentiometer”
0 =
Function “external potentiometer” Off
7 = Lift-dependent speed limiting with potentiometer
(if parameter 911= 912).
7
0
0
127
AkS Acoustic signal for V8xx ON/OFFI
1
0
0
128
ASd Start start backtack
, when command “start” is given by
covering the light barrier (see parameter 129)
ms
2000
0
0
129
ALS Machine start by covering the light barrier (only in conjunction with
parameter 132 = 1)
0 = Function Off
1 = Light barrier covered
pedal forward (>1)
machine run pedal
controlled.
2 = Pedal forward (>1)
light barrier covered machine run
pedal
controlled.
3 = Light barrier covered
machine run at automatic speed n12
(without pedal)
4 = Pedal forward (>1)
light barrier covered machine run
pedal
controlled.
5 = Light barrier covered
machine run at automatic speed n12
(without pedal)
Attention!
If 129 = 3, the machine starts immediately after covering
the light barrier without influence by the pedal! It can be stopped only
by uncovering the light barrier or by machine run blockage!
If machine run blockage is disabled, the machine starts immediately
even if the light barrier is still covered!
6 = The same as 3, run without pedal when covering the light curtain,
however start up only when FI is lowered.
3
0
0
130
LSF Light barrier filter for knitted fabrics
1
0
0
131
LSd 0 =
Light barrier sensing “covered”
1 = Light barrier sensing uncovered
1
0
1
132
LSS 0 = Machine start possible with light barrier uncovered or covered.
1 = Machine start blocked with light barrier uncovered if parameter
131 = 1.Machine start blocked with light barrier covered,
1
0
1
Summary of Contents for AB620A5035
Page 98: ......
Page 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Page 100: ... AB620A5035 Parameter List 94 For your notes ...
Page 101: ... AB620A5035 Parameter List 95 For your notes ...
Page 102: ... AB620A5035 Parameter List 96 For your notes ...
Page 103: ... AB620A5035 Parameter List 97 For your notes ...