212°F
122°F
140
194
176
158
34
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes
without having to give prior notice or replace this manual.
OPERATING AND MAINTENANCE MANUAL
FOR LOGICA TWIN MID
EN
9.3
TROUBLE-SHOOTING
PROBLEM
CAUSE
SOLUTION
The sauna does not respond to any
commands.
- No electric current
- Power supply
- Check the general electrical
distribution board and switch.
Internal light/ colour-therapy
doesn’t work.
Connector plug not connected
Check the cable connection to the
ceiling light fitting, located above
the sauna.
Heater doesn’t heat up.
1) The safety thermostat has
intervened
2) Stones incorrectly positioned
1) Call the technical help line.
2) Check that the stones are not
positioned in a way that obstructs
the air circulation inside the heater.
Contact an approved service centre for anything not covered by the above table.
Never, under any circumstances, attempt any repair work that is not included in the ‘SOLU-
TIONS’ column of the above table.
If the heater is not working, the Remote LED will start flashing rapidly.
See the table below for a list of other possible errors.