OPERATING AND MAINTENANCE MANUAL FOR AQUASTEAM,
AQUASTEAM MAXI, EASYSTEAM
EN
53
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or replace this manual.
Please note: the information in the table below and the action to take is intended for the use
of the assistance centre personnel and others qualified to install/maintain the equipment.
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.
TROUBLE-ShOOTING
Error message
Meaning
Error
Cause
Solution
Critical errors
A peripheral device
has not been found
on the bus.
Lack of
communication
with 1 or more
devices.
One of the devices
is not receiving
power or is not
connected.
1. Check the device
connections.
2. Run the start-up
sequence.
The panel
signalling the error
is not receiving
polling from the
master.
Lack of
communication
with 1 or more
devices.
One of the devices
is not receiving
power or is not
connected.
1. Check the device
connections.
2. Run the start-up
sequence.
Peripheral device
not recognised by
the bus.
Lack of
communication
with 1 or more
devices.
One of the devices
is not receiving
power or is not
connected.
1. Check
the device
connections.
2. Run the start-up
sequence.
Non-critical errors
Boiler full too soon. The boiler filled
too quickly during
initial rinsing or final
emptying.
Outlet valve not
working.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.
Boiler not yet full.
The boiler didn’t
fill within the
prescribed time
limit during initial
rinsing or final
emptying.
Lack of water in
the system or the
inlet valve filter is
blocked.
1. Check that the
water tap is turned
on.
2. Check that there
is water in the
system.
3. Check that
the filter at the
entrance to the
inlet valve is not
blocked.
Boiler not yet
empty.
The water level in
the boiler remained
too high for too
long during initial
rinsing or final emp-
tying.
Outlet valve not
working.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.