Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - 0300 - 22320 - [email protected]
17
Date & time
Press OTHER and then open the WEEKDAY menu.
Set the correct date and then press return to get back to
the Other setting menu.
Press TIME to open the menu for the clock. Set the cor-
rect local time.
▀
Program setup - date & time
Weekday
Time
Calibr. sensors
Function test
Alarms
English
Start guide
Other settings
Flame sens
Igniter
Feeder
Fan
Compressor
Solenoid valve
Test air clean
Convection clean
Shunt motor 1 (+/-)
Radiator pump 1
Shunt motor 2 (+/-)
Radiator pump 2
Function test
0%
Off
Off
100%
Off
Off
Off
Off
Off
Off
Off
Off
Function test of shunt motors
Press OTHER and then open the FUNCTION TEST menu.
Depending on what functions the boiler have been deli-
vered with a different view will appear in the function test
menu.
Test the following functions:
Shunt motor 1 (also 2 and 3 if applicable) needs to con-
trolled so that they open in the right direction. Press +/-
and check that they very slowly open in the right direction.
Note that it can be either clockwise or counterclockwise
depending on how the shunt valve has been set up. If the
motor is operating in the wrong direction the power freed
phases needs to be switched.
▀
Program setup - function test
>
>
>
>
>
>
>
Weekday
Time
Calibr. sensors
Function test
Alarms
English
Start guide
Other settings
>
>
>
>
>
>
>