Technical specifications
Connected voltage:
8 – 12 V
Door opener:
standard door opener 8 V or
12 V, depending on the
transformer being used
Waiting time:
trimmer P 1 approx.1 – 20 sec.
Enabled time period:
trimmer P 2 approx.1 – 10 sec.
(accessible only when cover
removed).
Switching voltage:
42 V max.
Switching current:
5 A max.
Mounting:
surface mounted or locked
onto a standard rail
(power panel installation)