EMERGENCY EXIT DEVICES INSTALLATION ACCORDING TO EN 179
The following lock cases and handles are approved to be installed together in an emergency
exit door. Strike plate Z09XSBL-01 ... Z09XSBL-04 must be used in the installation.
EN 179
PANIC EXIT DEVICES INSTALLATION ACCORDING TO EN 1125
The following lock cases and push bars are approved to be installed together in a panic exit door.
Strike plate Z09XSBL-01 ... Z09XSBL-04 must be used in the installation.
Recommended distance from a floor to a handle or to a push bar is between
900mm - 1100mm.
Lubricate the bolts of the lock case at least once a year. Use vaseline type lubrication.
Note!
ASSA ABLOY
will not be liable for products in case these instructions are not followed.
EN 1125
Functional check after installation:
Emergency exit (active) side and functional sensitivity tests:
- Use the handle of exit side. Exit side is correctly set if the bolt goes inside the lock case
irrespective of the electrical control.
-
In the profile door locks
the force of handle is about 15 N (approximately 1.5 kg weight
at a 100 mm distance from the pivot of the handle opens the lock).
-
In the wooden door locks
the force of handle is about 25 N (approximately 2.5 kg weight
at a 100 mm distance from the pivot of the handle opens the lock). According to EN 179
the force of handle must be less than 70 N.
- Close the door slowly and check that the lock deadlocks.
- Check that the bolts slide freely into the strike plate.
The safety features of this product are essential to its compliance with EN 179. No
modification of any kind, other than those described in these instrictions, are permitted.
Functional check after installation:
Panic exit (active)side and functional sensitivity tests:
- Push the push bar towards the door on the exit side. Exit side is correctly set if the bolt goes
inside the lock case irrespective of the electrical control.
- Force to open the lock by pushing the push bar is about 60 N (approximately 6kg). According
to EN 1125 it must be less than 80 N.
- Close the door slowly and check that the lock deadlocks.
- Check that the bolts slide freely into the strike plate.
Note! The length of the push bar must be at least 60 % of the width of the door.
The safety features of this product are essential to its compliance with EN 1125. No
modification of any kind, other than those described in these instrictions, are permitted.
1016, 1023, 1056, 1070,
1080, 1088, 1090, 1117,
1118, 1119, 1137, 1146,
1155, 1160, 1161, 1162,
1177, 1178, 1191, 0612,
0616, 0617, 0619, 0625,
0627, 0628, 0646, 0662,
0665, 0680, 0681, 0682,
0688
309X / 409X
IKON
DO 20.15.02
FSB
DO 20.03.01, DO 20.03.02
HEWI
DO 20.13.01, DO 20.13.02
Wooden style
111, 111.23,
114.23GK, 131, 132,
111X, 113X, 114X,
161X, 163X, 171X,
112X, 165X, 166X
IKON
DO 20.15.01
Narrow style
309X / 409X
S6B3, S6B6
S6B8
S326, S426, S4K3
S4K6
709X
709X
ENGLISH
309X / 409X / 709X
309X / 409X / 709X
8000-00-1100 (-), 8000-20-1100 (PZ)
8000-00-1100 (-), 8000-21-1100 (RZ)
effeff
DO 30.04
8000-00-1100 (-), 8000-10-1100 (PZ)
8000-00-1100 (-), 8000-11-1100 (RZ)
Narrow style
Wooden style
effeff
DO 30.04
TESA
DO 30.06
UNIVERSAL SERIE
19709G9xx
JPM
DO 30.05
D
ORMA
990000-XX-0A, 990100-XX-0A,
990001-XX-0A, 990101-XX-0A,
991000-XX-0A, 991100-XX-0A,
991001-XX-0A, 991101-XX-0A
(870000-30-0A, 870000-31-0A,
870000-32-0A, 870000-33-0A)
7