Features &
Controls:
Front Panel
10
Air Pressure
•
Pull out the air pressure regulator knob to unlock it (bottom left knob).
•
Turn the knob clockwise to the desired pressure setting.
•
To reduce the pressure, turn the knob counter-clockwise until pressure
is lower than needed. Then increase the pressure until you reach the
correct setting.
•
Push the knob in to lock the pressure setting.
Vacuum
During initial testing and setup we recommend that you keep the vacuum
control shut off (turned completely clockwise; do not force).
Vacuum is required when dispensing thin fluids.
•
Turn the knob counter-clockwise to the desired vacuum setting.
See page 12 for details on using the Vacuum control.
Air Output Port
Push in the black quick-connect from the EFD adapter assembly to
the air output port, located on the front of the Ultra 870. Twist to lock.
Note: air does not flow through the port until a quick-connect is installed.
air pressure regulator
vacuum regulator
air output
pressure gauge