EFD Ultra 870 Series User Manual Download Page 10

R

psi

100 x kPa

bar

0

50

100

10

90

40

30

20

60

70

80

0

1

2

3

4

5

6

7

+

+

Features &
Controls: 
Front Panel

10

Air Pressure

Pull out the air pressure regulator knob to unlock it (bottom left knob).

Turn the knob clockwise to the desired pressure setting.

To reduce the pressure, turn the knob counter-clockwise until pressure
is lower than needed. Then increase the pressure until you reach the
correct setting.

Push the knob in to lock the pressure setting.

Vacuum

During initial testing and setup we recommend that you keep the vacuum
control shut off (turned completely clockwise; do not force).

Vacuum is required when dispensing thin fluids.

Turn the knob counter-clockwise to the desired vacuum setting.

See page 12 for details on using the Vacuum control.

Air Output Port

Push in the black quick-connect from the EFD adapter assembly to 
the air output port, located on the front of the Ultra 870. Twist to lock.
Note: air does not flow through the port until a quick-connect is installed.

air pressure regulator

vacuum regulator

air output 

pressure gauge

R

psi

psi

100 x kPa

bar

00

50

100

10

0

10

90

40

30

20

60

70

80

0

1

2

3

4

5

6

7

+

R

psi

100 x kPa

bar

0

50

10

0

10

90

40

30

20

60

70

80

0

1

2

3

4

5

6

7

+

+

air pressure regulator

vacuum regulator

R

psi

bar

10

0

2

3

4

5

air output

Summary of Contents for Ultra 870 Series

Page 1: ...User s Guide Ultra 870 Dispenser Electronic pdf files of EFD manuals are also available at www efd inc com manuals html Ultra 870 A NORDSON COMPANY...

Page 2: ...0 556 3484 between 8 30 a m and 5 30 p m Eastern time In Europe call 44 0 1582 666334 In Asia call 86 21 5854 2345 In all other areas call your authorized EFD distributor or 1 401 434 1680 The EFD Ple...

Page 3: ...ringe Barrel 13 Syringe Barrel Loaders 14 Test Procedures 15 Schematic Parts List 16 Troubleshooting 17 Helpful Hints 18 Productivity Tools 19 Warranty Back Cover This manual is for the express and so...

Page 4: ...on operation and service are not followed Personal Safety To prevent injury follow these instructions Do not operate or service equipment unless you are qualified Do not operate equipment unless safet...

Page 5: ...ers are located Clean maintain test and repair equipment according to the instructions in your equipment documentation Use only replacement parts that are designed for use with original equipment Cont...

Page 6: ...00 Weight 0 95 kg 2 08 lb Cycle rate Exceeds 600 cycles per minute Air input 80 to 100 psi 5 5 to 6 9 bar Air output 0 to 100 psi 0 to 6 9 bar Note Specifications and technical details are subject to...

Page 7: ...uctions in the enclosed Welcome letter to contact your EFD representative Unpack the Unit Warranty 2 Install Barrel Holder 3 Note Clean dry filtered factory air is required to meet warranty If your ai...

Page 8: ...ap the safety clip on the adapter hose closed to prevent dripping Remember to unsnap the clip when ready to dispense Replace tip cap with an EFD precision dispense tip Place syringe barrel in the barr...

Page 9: ...9 Getting Started Completed Setup Note Each number corresponds to the appropriate Getting Started step...

Page 10: ...t off turned completely clockwise do not force Vacuum is required when dispensing thin fluids Turn the knob counter clockwise to the desired vacuum setting See page 12 for details on using the Vacuum...

Page 11: ...2000F755 Warning Bottled nitrogen can be used If high pressure bottled air or nitrogen is used a high pressure regulator must be installed on the bottle and set at 100 psi 6 9 bar maximum In this inst...

Page 12: ...FlowTM piston push the white piston down until it comes in contact with the fluid 2 Attach the syringe to the EFD adapter assembly 3 Snap the safety clip tightly closed to prevent any dripping 4 Remov...

Page 13: ...e syringe barrel is now ready for use Filling procedure for thick fluids If your fluid is thick or non leveling you can spoon it into the syringe barrel with a spatula Or if the fluid comes packed in...

Page 14: ...p your work area clean save time and reduce the chance of entrapped air in the fluid 1 You could use the EFD 920BL barrel loader Pack the fluid into the 12 ounce cartridge as shown Then place the pre...

Page 15: ...trolled flow not too fast not too slow 6 Push the air pressure knob in to lock setting 7 Rest the dispense tip on the Dot Standards sheet 8 Press the foot pedal to activate the dispense cycle Release...

Page 16: ...x 6 mm push in elbow 7 2036 Fitting 1 8 FPT x 1 4 barb 8 2004B Female quick connect 9 4042 Bulkhead stop fitting 4 mm 10 1417 Bulkhead fitting 4 mm 11 1418 Differential union tee 4 6 mm 12 2002SCR Rep...

Page 17: ...use inconsistency For best results remove all air bubbles Material suck back 1 Use a SmoothFlow piston or LV Barrier to prevent material being drawn into the dispenser 2 Another option is to order the...

Page 18: ...dly and do not tip the barrel Vacuum may pull fluid into the adapter hose or if the syringe barrel is tipped fluid may flow back into the dispenser 6 Always use new EFD syringe barrels and tips Carefu...

Page 19: ...ify EFD part 2441 Liquid filter trap Helps to prevent fluid from being sucked back into the dispenser Specify EFD part 1000FLT Y Five micron regulator Required for production areas where clean dry fil...

Page 20: ...atsoever in connection therewith This warranty is valid only when clean dry filtered air is used EFD makes no warranty of merchantability or fitness for a particular purpose In no event shall EFD be l...

Reviews: