The Ultra 2400 dispensing workstation allows you to store the dispense time, pressure and vacuum
settings for up to 16 different job programs. Programs are saved even with power removed and will
remain in storage unless changed or erased intentionally.
Job programs are identified as Memory 1 through Memory 16.
Note: Dispense time is automatically adjusted when you select an individual job program. Settings for
pressure and vacuum are stored and can be displayed but you need to manually adjust the pressure
and vacuum regulator knobs to match the stored settings for these values.
To Save a Job Program
1.
From
TIMED
or
TEACH
mode, set the dispense time, air pressure and vacuum settings to
create a correct deposit size. When you are in
TEACH
mode, press
SAVE
after you create your
settings, then return to
TIMED
mode.
2.
Press
MENU
. Use the up/down arrows to highlight
SAVE JOB
. Press
SELECT
.
3.
Use the up/down arrows to select the correct job program in which to save these settings
(example, Memory 1 or Memory 2). Remember: to prevent accidental data loss, review the
contents of each job program before selecting and storing a new job into memory.
4.
Press
SAVE
. This automatically saves the settings in the job program and returns you to the
Home screen.
5.
Press the foot pedal or finger switch to activate the dispense cycle. The Ultra 2400 workstation
will make the deposit based on the settings in the selected job program.
To Work in a Saved Job Program
1.
Press
MENU
. Use the up/down arrows to highlight
MEMORY
. Press
SELECT
.
2.
Use the up/down arrows to scroll through the individual jobs until you reach the correct Memory
number.
3.
Press and hold
SETTINGS
to see the stored pressure and vacuum settings for the job.
Remember: Dispense time automatically adjusts when you select a job program. Releasing the
Settings button displays the current values for pressure and vacuum, not the stored values. To
retrieve the stored values, manually adjust air pressure and vacuum, based on the pressure and
vacuum shown when you press Settings.
4.
Press the foot pedal or finger switch to activate the dispense cycle. The Ultra 2400 will
automatically make the deposit based on the settings in the selected job program.
5.
To escape from Memory, press
MENU
. Then press
TIMED
to return to the Home screen. At this
point, you are still in the current memory setting for the previous job program, but you are free
to change time, pressure and vacuum without impacting the stored settings in memory.
Memory