7
- If the appliance just fitted with supply leads but does not come already fitted with a plug, then permanently connect
to fixed wiring as follow:
- The “yellow/green” earth wire, which must be connected to terminal, has to be about 10mm longer than the other
wires; the “blue” neutral wire has to be connected to the terminal marked with letter N.
“Black, brown, red” live wires have to be connected to terminal L. Mains connection can also be made by fitting a
double pole switch with a minimum gap between the contacts of 3mm, proportionate to the load and complying
with the regulations in force.
The yellow/green earth wire should not be controlled by the switch.
The plug or a double pole switch used for mains supply connection should be easy to get at, once the appliance is in
position.
IMPORTANT :
position the mains supply cable so that it is never subjected to a temperature which is
ć
more than 50 above ambient temperature.
- The electrical safety of the appliance
can only be guaranteed when it has been correctly connected to an efficient
earthed power supply, as laid down in the regulations for electrical safety.
- The manufacturer cannot be held responsible for any damage to persons or objects due to lack of an earth
connection.
WARNING: THIS APPLIANCE MUST BE EARTHED
- Check that the power rating of the mains supply and of the sockets are suitable for the maximum power of the
appliance as indicated on the specification plate.
- plug should be accessible after installation. Fit the plug into a socket fitted with a third contact which corresponds
with the earth connection. This should be properly connected.