EemaX HA008240 Installation Instructions & Owner'S Manual Download Page 6

   

5   

5-­‐   ELECTRICAL   INSTALLATION   

Eemax   recommends   that   this   product   be   installed   by   a   licensed   and   qualified   electrician   in   accordance   with   all   
applicable   national,   state,   provincial,   and   local   electrical   codes.   As   with   all   electrical   appliances,   under   no   
circumstances   should   you   attempt   to   install,   repair   or   disassemble   this   water   heater   without   first   shutting   off   all   
power   to   the   unit   directly   at   the   fuse   or   breaker   box.   

Make   sure   to   shut   off   all   breakers.   SERIOUS   BODILY   

INJURY   OR   DEATH   COULD   OCCUR   IF   YOU   IGNORE   THIS   WARNING.   

All   wiring   (wire   gauge)   and   circuit   protection   (breakers)   must   comply   with   the   U.S.   National   Electrical   Code   (NEC)   
in   the   USA,   or   the   Canadian   Electrical   Code   (CEC)   in   Canada.   Failure   to   do   so   could   result   in   property   damage   
and/or   personal   injury,   and   void   your   warranty.   Note:   The   Canadian   Electrical   Code   generally   requires   that   all   
supply   wires   and   corresponding   circuit   protection   used   for   domestic   hot   water   heating   and   hydronic   heating   
applications   be   sized   to   a   minimum   of   125%   of   the   maximum   current   rating   of   the   heater   (see   model   
specifications   below   for   details).   
Before   installing   this   product,   ensure   that   the   home   has   sufficient   electrical   power   available   to   handle   the   
maximum   amperage   load   of   the   applicable   model.   

IMPORTANT   NOTES:   

Model   HA008240,   HA011240,   and   HA013240   require   1   set   of   wires   and   ground   

(see   wiring   diagram)

   

Model   HA018240   requires   2   sets   of   wires   and   ground   

(see   wiring   diagram)

   

Model   HA024240   and   HA027240   require   3   sets   of   wires   and   ground   

(see   wiring   diagram)

   

Model   HA036240   requires   4   sets   of   wires   and   ground

   (see   wiring   diagram)   

Please   see   electrical   specifications   by   model   and   wiring   diagram   on   the   next   page   for   additional   electrical   
information.   
Each   set   of   wires   must   be   connected   to   its   own   individual   double   pole   breaker.   

   

Installation   Instructions   

STEP   1:

   Take   each   wire   pair   and   connect   them   to   one   breaker   (see   wiring   diagram).   Make   sure   that   each   breaker   

is   connected   with   one   black   wire   and   one   red   wire   

STEP   2:

   Using   a   suitable   wire   gauge   that   meets   all   applicable   electrical   codes   for   the   size   of   the   breakers   used,   

run   the   correct   sets   of   wire   from   the   home’s   main   breaker   panel   to   the   tankless   water   heater.         

STEP   3:

   A   separate   ground   conductor   for   each   incoming   circuit   is   required.   

STEP   4:

   DOUBLE   CHECK   the   electrical   connections   to   make   sure   they   are   correct   and   that   all   wire   connections   

are   tight   and   secure.   Also   confirm   that   the   correct   breaker   size   and   wire   gauge   has   been   used   and   confirm   that   
the   unit   has   been   connected   to   a   ground   in   accordance   with   applicable   codes.   

STEP   5:

   Confirm   that   all   the   air   has   been   purged   from   the   water   lines   prior   to   turning   on   power   to   the   unit.   Refer   

to   STEP   2   in   the   plumbing   installation   section.   
   

CAUTION:

   Ensure   that   you   have   made   the   correct   connections.   You   must   follow   the   wire   connection   as   shown   

to   ensure   proper   operation   of   the   unit.   If   you   mix   up   one   set   of   wires   with   another,   the   unit   will   not   operate   
correctly   even   though   it   turns   on   and   otherwise   appears   to   function   properly.   
   
The   water   heater   is   now   installed   and   ready   to   use!   Follow   the   General   Operating   Instructions   to   complete   the   
setup.   We   highly   recommend   that   this   is   done   with   the   homeowner   present.   
   
   

   

Summary of Contents for HA008240

Page 1: ...unit directly at the circuit breaker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY...

Page 2: ...g valve complying with the Standard for Temperature Actuated Mixing Valves for Hot Water Distribution Systems ASSE 1017 be installed The chart shown above may be used as a guide in determining the proper water temperature for your home DANGER Households with small children disabled or elderly persons may require a 120 F or lower thermostat setting to prevent contact with HOT water The temperature ...

Page 3: ...s at any time please contact us directly at Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING ...

Page 4: ...cal boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure to follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active water leak de...

Page 5: ...s NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe we recommend that a T ...

Page 6: ...nd see wiring diagram Model HA036240 requires 4 sets of wires and ground see wiring diagram Please see electrical specifications by model and wiring diagram on the next page for additional electrical information Each set of wires must be connected to its own individual double pole breaker Installation Instructions STEP 1 Take each wire pair and connect them to one breaker see wiring diagram Make s...

Page 7: ...50 AMPS REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 x 6 AWG 1 x 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Wiring Diagram Circuit Breaker 1 L1 L1 Circuit Breaker 2 L2 L2 Circuit Breaker 3 L3 L3 Circuit Breaker 4 L4 L4 BLACK RED BLACK RED BLACK RED BLACK RED HA008240 HA011240 HA013240 require 1 set of breaker and ...

Page 8: ...ter and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit temperature from becoming too cool To learn more about flow regulators or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Regulator 1 Find your model in the chart on the left 2 Choose the column with...

Page 9: ...er leak we recommend the following maintenance Inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be addressed Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten the water heater connections at th...

Page 10: ...hat the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When used with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may also have ...

Page 11: ...ving the cover to change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 1 Hot Water Outlet 5 Adjustment Knob Temperature Control 9 Electrical Strain Relief 2 Cold Water Inlet 6 Wire Connection 10 Mounting Bracket 1 3...

Page 12: ... USA AND CANADA Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com ...

Reviews: