background image

   
   

   
   

   
   

   

   

   

INSTALLATION   INSTRUCTIONS   &   HOME   OWNERS   MANUAL   

   

   

HOMEADVANTAGE   II   

HA008240   |   HA011240   |   HA013240   |   HA018240   |HA024240   |   HA027240   |   HA036240   

   
   
   

IMPORTANT   SAFETY   INFORMATION   

When   installing   or   using   any   high   voltage   electrical   appliance,   basic   safety   precautions   should   always   be   
followed.   Under   no   circumstance   should   you   attempt   to   clean,   install,   inspect,   repair,   disassemble   or   
otherwise   service   this   water   heater,   without   first   shutting   off   

all

   power   to   the   unit   directly   at   the   circuit   

breaker   box.   

SERIOUS   BODILY   INJURY   OR   DEATH   COULD   OCCUR   IF   YOU   IGNORE   THIS   WARNING.   

THIS   PRODUCT   SHOULD   BE   INSTALLED   BY   A   QUALIFIED   ELECTRICIAN   AND   A   QUALIFIED   PLUMBER   IN   
ACCORDANCE   WITH   ALL   NATIONAL,   STATE,   PROVINCIAL   AND   LOCAL   ELECTRICAL   &   PLUMBING   CODES.   
PLEASE   READ   THESE   INSTRUCTIONS   THOROUGHLY   AND   COMPLETELY   PRIOR   TO   INSTALLATION   &   USE.   
FAILURE   TO   DO   SO   COULD   CAUSE   PROPERTY   DAMAGE,   SERIOUS   INJURY,   OR   DEATH.      

   
This   manual   should   be   given   to   the   homeowner   after   installation   and   should   be   retained   for   future   reference.   

   

   

Tested   and   certified   by   the   Water   Quality   Association   against   NSF/ANSI   372   for   lead   free   
compliance.   

Summary of Contents for HA008240

Page 1: ...unit directly at the circuit breaker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY...

Page 2: ...g valve complying with the Standard for Temperature Actuated Mixing Valves for Hot Water Distribution Systems ASSE 1017 be installed The chart shown above may be used as a guide in determining the proper water temperature for your home DANGER Households with small children disabled or elderly persons may require a 120 F or lower thermostat setting to prevent contact with HOT water The temperature ...

Page 3: ...s at any time please contact us directly at Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING ...

Page 4: ...cal boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure to follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active water leak de...

Page 5: ...s NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe we recommend that a T ...

Page 6: ...nd see wiring diagram Model HA036240 requires 4 sets of wires and ground see wiring diagram Please see electrical specifications by model and wiring diagram on the next page for additional electrical information Each set of wires must be connected to its own individual double pole breaker Installation Instructions STEP 1 Take each wire pair and connect them to one breaker see wiring diagram Make s...

Page 7: ...50 AMPS REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 x 6 AWG 1 x 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Wiring Diagram Circuit Breaker 1 L1 L1 Circuit Breaker 2 L2 L2 Circuit Breaker 3 L3 L3 Circuit Breaker 4 L4 L4 BLACK RED BLACK RED BLACK RED BLACK RED HA008240 HA011240 HA013240 require 1 set of breaker and ...

Page 8: ...ter and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit temperature from becoming too cool To learn more about flow regulators or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Regulator 1 Find your model in the chart on the left 2 Choose the column with...

Page 9: ...er leak we recommend the following maintenance Inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be addressed Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten the water heater connections at th...

Page 10: ...hat the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When used with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may also have ...

Page 11: ...ving the cover to change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 1 Hot Water Outlet 5 Adjustment Knob Temperature Control 9 Electrical Strain Relief 2 Cold Water Inlet 6 Wire Connection 10 Mounting Bracket 1 3...

Page 12: ... USA AND CANADA Eemax Inc 400 Captain Neville Drive Waterbury CT 06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com ...

Reviews: