GENERAL SAFETY
The “Eemax three Module, Single Phase” heater is specifically designed to take in cold water
and heat it to temperatures suitable for normal domestic usage up to a maximum of 140 F(60
C). To obtain optimum performance and energy savings, the unit should be located as
near as possible to the point of use. “Thermostatic” models indicated by the letters “T2T or
T3” after the model number, these models and only these, can be fed with pre-heated water
and be used to boost temperature
The unit is supplied with 3/4” NPT pipe connections. Under no circumstances use a blow
torch on pipe which is connected to the heater (serious damage to the electronic flow
switch will result). Carefully use Teflon tape, ensuring no debris enter the heater. Do not
use pipe dope.
Also, ensure that the pipes are clear of installation debris before fitting the heater.
THIS HEATER MUST HAVE THREE DEDICATED INDEPENDENT
208/240V CIRCUITS, USING CORRECTLY RATED WIRES AND
CIRCUIT BREAKERS.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE. REFER TO
THIS MANUAL FOR ASSISTANCE OR CONSULT THE LOCAL ELECTRIC UTILITY FOR
FURTHER INFORMATION.
FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY.
WARNING
WARNING
WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: THIS WATER HEATER MAYBE
EQUIPPED FOR ONE VOLTAGE TYPE ONLY: CHECK THE RATING PLATE ON THE FRONT
COVER OF UNIT FOR THE CORRECT VOLTAGE. DO NOT USE THIS WATER HEATER WITH
ANY OTHER VOLTAGE OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE.
FAILURE TO USE THE CORRECT VOLTAGE CAN CAUSE PROBLEMS WHICH CAN RESULT
IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. IF YOU HAVE ANY
QUESTIONS OR DOUBTS CONSULT EEMAX OR YOUR ELECTRIC COMPANY.
WARNING
HAZARD OF ELECTRICAL SHOCK! BEFORE REMOVING THE COVER OR SERVICING THE
WATER HEATER, MAKE SURE THE ELECTRICAL SUPPLY TO THE WATER HEATER IS
TURNED “OFF”. FAILURE TO DO THIS COULD RESULT IN DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
2