Optional Enclosure Heater
1) Attach heat tape and foam insulation to all
lengths of inlet and outlet water piping that are
exposed to freezing temperatures. We
recommend a rating of -30 degrees F at 10
miles per hour wind. Connect the heat tape to
an independent source of electrical power.
FAILURE TO ATTACH HEAT
TAPE AND INSULATION TO EXPOSED INLET
AND OUTLET PIPES WILL VOID THE
WARRANTY.
2) Set the thermostat on the enclosure heater,
located at the upper left corner in the
enclosure, to 40 - 70 degrees F.
Note: Heater Fan continuously operates to
recirculate air in the enclosure. The heater coil
will activate based on thermostat set point.
19
Note: Power must be applied to the water heater for the
freeze protection system to operate. If power is not applied
ensure the system is completely drained. Neglecting to do
so will damage the heater and void the warranty.