2
This manual provides installation information for the following:
25 Ton
40 Ton
50 Ton
55 Ton
60 Ton
65 Ton
75 Ton
100 Ton
100 Ton DX
120 Ton
Elite 110
Elite 110/65 D.O.
Porta Power
Environmental Requirements at Work Station
The work station environment for your machine must meet the following
minimum requirements:
• Floor
area:
Assure that the machinery work area provides
for a stable, adequately sized and load rated fl oor area for
material movement to and from the machinery work stations.
• Shelter:
Edwards Ironworkers are designed for indoor use
only. Protect your Ironworking machinery from water, salts
and corrosive elements.
• Lighting:
500LUX (50 footcandles) minimum.
• Operating
Temperature:
This equipment will operate
correctly in its intended ambient, at a minimum between
+5° C and +40°C.
• Relative
Humidity:
This equipment will operate correctly
within an environment at 50% RH, +40°C. Higher RH may
be allowed at lower temperatures. Measures shall be taken
by the Purchaser to avoid the harmful effects of occasional
condensation.
• Altitude:
This equipment will operate correctly up to 1000m
above mean sea level.
•
Transportation and Storage:
This equipment will withstand,
or has been protected against, transportation and storage
temperatures of -25°C to +55°C and for short periods up to
+70°C. It has been packaged to prevent damage from the
effects of normal humidity, vibration and shock.
Electrical Requirements at Work Station
Locate your Porta Power directly adjacent to your power supply. Con-
fi rm that power supply is not connected in series with other machinery.
Provide dedicated electrical socket and circuit breaker for each machine
installed. Edwards Machines are protected from voltage variations pro-
vided the variation does not /- 10% machine rating.
Installation Requirements
Electrical Performance Specifi cation
Machine
Motor
#
Type Brand
60Hz/V FLA
50Hz/V FLA
25 Ton
116676
1Hp 1~
Leeson
60 Hz 115/208-230
12/6
50 Hz 110/220
13/6
40, 50, 55, 60 Ton, 132089
5Hp 1~
Leeson
60 Hz 230
19
50 Hz 208-220
23-22
Porta-Power
132077
5Hp 3~
Leeson
60 Hz 208-230/460
14/7
50 Hz 190/380
16/8
CEM3615T-5
5Hp 3~
Baldor
60 Hz 575
5
65, 75, 100 Ton,
132089
5Hp 1~
Leeson
60 Hz 230
19
50 Hz 208-220
23-22
Elite 110
140809
7.5Hp 3~
Leeson
60 Hz 208-230/460
22-21/10
50 Hz 190/380
24/12
Elite 110/65 D.O.
CEM3710T-5
7.5Hp 3~
Baldor
60 Hz 575
8
141140
7.5Hp 1~
Leeson
60 Hz 230
36
100DX, 120 Ton
CEM3714T
10Hp 3~
Baldor
60 Hz 208-230/460
25-24/12
EM3714T-5
10Hp 3~
Baldor
60 Hz 575
10
CEM3714T-50
10Hp 3~
Baldor
50 Hz 220/380/440
28/16/14
CL3712T
10Hp 1~
Baldor
60 Hz 208-230
38
Summary of Contents for Porta Power
Page 5: ...3 Signal Word Panel Machine Back ...
Page 15: ...1107 Sykes St Albert Lea MN 56007 800 373 8206 www edwardsironworkers com S EDWARDS ...
Page 22: ...5 Operations Diagram Machine Back Drain Plug ...
Page 26: ...9 ...
Page 27: ...1107 Sykes St Albert Lea MN 56007 800 373 8206 www edwardsironworkers com S EDWARDS ...
Page 33: ...1107 Sykes St Albert Lea MN 56007 800 373 8206 www edwardsironworkers com S EDWARDS ...