Indicator
Name
LED
colour
Location
Meaning
Green mode/
Standby
Green
Front panel (item 10)
Illuminates continuously when the
pump is in Green mode/standby
mode.
Flashes to indicate that the pump is
warming up. Refer to
on page 57.
Warning
Yellow
Front panel (item 8)
Rear panel (item 6)
Illuminates continuously to indicate
a pump warning.
Flashes to indicate an internal
communication problem. Refer to
Pump controller communications
page 173.
Alarm
Red
Front panel (item 9)
Rear panel (item 7)
Illuminates continuously to indicate
a pump alarm.
Flashes to indicate an internal
communication problem. Refer to
Pump controller communications
page 173.
Ethernet LAN
Green
Rear panel (item 1)
Flashes to indicate that there is a
network traffic and Ethernet packets
are being received.
Ethernet Link
Yellow
Rear panel (item 2)
Illuminates continuously to indicate
that the Ethernet protocol is active.
4.2.1 Determining the pump status
It is not possible to fully determine the pump status by referring to only one status LED.
By looking at both the running LED and Green mode/standby LED together, the user can
work out the pump status. Refer to
Table 20
Pump status
Pump running LED
Green mode/Standby LED
Pump status
Off
Off
Pump stopped
Flashing
Flashing
Pump warming up
Flashing
Illuminated continuously
Pump is in Green mode/standby
mode
Illuminated
continuously
Off
Pump is on-process
Flashing
Off
Pump is shutting down
4.3 Green mode/standby mode
Green mode is used to reduce the power and purge gas consumption of the pump when
off process. All dry pumping systems can support up to 9 different Green mode
configurations. By default, only one green mode is enabled. To enable alternative Green
mode configurations please contact our local service representative.
Page 57
M58800880_H - Operation
Summary of Contents for 9773512584
Page 6: ...This page has been intentionally left blank ...
Page 87: ...Figure 19 GXS160 installation drawing Sheet 4 Page 83 M58800880_H Installation drawings ...
Page 178: ...This page has been intentionally left blank ...
Page 179: ...This page has been intentionally left blank ...
Page 180: ...edwardsvacuum com ...