The pneumatic regulator is pre-set to 50 ± 5 psig in the factory and does not need to be
adjusted. The pneumatic regulator is shown in
Figure: DP clean assembly for the pump
, item 5 for the pump
‑
only systems. For pump and booster combination
systems, the regulator is contained within the pump enclosure.
To use an inert gas in place of atmospheric air as the DP clean purge gas, remove the air
filter and in its place connect up the inert gas supply. For pump and booster
combinations, the air filter is on the rear pump panel (refer to
connectors on the rear of the pump (system with rear exhaust and castors/levelling feet
, item 12). For pump
‑
only systems, refer to
Figure: DP clean assembly for the pump
, item 1. Refer to
DP clean high flow purge/solvent flush option
on page 27
for information about fittings and typical purge gas flows.
A solvent suction pipe is provided with the pump. When only performing a high flow
purge procedure, the solvent suction pipe will not be needed. When performing a
solvent flush, fit the solvent suction pipe only when ready to perform the DP clean
procedure. For pump and booster combinations, the solvent flush fluid connection is on
the rear pump panel (refer to
Figure: The controls/connectors on the rear of the pump
(system with rear exhaust and castors/levelling feet fitted)
, item 11). For pump
‑
only
systems, refer to
Figure: DP clean assembly for the pump only systems
, item 2.
A PDT is required to operate the DP clean high flow purge and solvent flush.
Figure 13 DP clean assembly for the pump only systems
1. Air filter
2. DP clean solvent flush fluid connection
3. Inlet spool
4. Pneumatic valve inlet connection
5. Pneumatic regulator
6. Optional connection to the pneumatic
valve sensor
7. Pneumatic valve
8. Pneumatic valve electrical connection
1. Air filter
2. DP clean solvent flush fluid connection
3. Inlet spool
4. Pneumatic valve inlet connection
5. Pneumatic regulator
6. Optional connection to the pneumatic
valve sensor
7. Pneumatic valve
8. Pneumatic valve electrical connection
Page 52
M58800880_H - Installation
Summary of Contents for 9773512584
Page 6: ...This page has been intentionally left blank ...
Page 87: ...Figure 19 GXS160 installation drawing Sheet 4 Page 83 M58800880_H Installation drawings ...
Page 178: ...This page has been intentionally left blank ...
Page 179: ...This page has been intentionally left blank ...
Page 180: ...edwardsvacuum com ...