Table 16
Water consumption data (GXS750/2600/4200)
Ambient (°C)
Water Temperature (°C)
40
30
20
40
25 SLM
2 bar dP
20 SLM
1.3 bar dP
15 SLM
0.75 bar dP
30
20 SLM
1.3 bar dP
20 SLM
1.3 bar dP
15 SLM
0.75 bar dP
20
15 SLM
0.75 bar dP
15 SLM
0.75 bar dP
15 SLM
0.75 bar dP
2.7 DP clean high flow purge/solvent flush option
Table 17
High flow purge/solvent flush data
Feature
Specification
Rating
Pneumatic valve gas
supply
Nitrogen or clean dry air
2.5 - 6.9 barg
(36 - 100 psig)
Pneumatic valve inlet
connection
3/8 inch compression fitting
High flow purge gas
Air, nitrogen or other inert
gas which is compatible with
process
Typically 170 slm (for the
GXS160 and GXS250 systems)
and 185 slm (for the GXS450
and GXS750 systems) at
atmospheric pressure at the
purge inlet connection
High flow purge air filter
1/2 inch NPT male
(available as a spare, refer to
on page 79)
DP clean solvent flush
fluid inlet connection
3/8 inch BSP male
DP clean solvent suction
pipe connection
3/8 inch BSP female
Notes:
1. The high flow purge/solvent flush kit is available as an option.
2. The DP clean solvent suction pipe is supplied with the pump but not fitted.
2.8 External evacuation system
The pumpdown performance on dry pumping systems fitted with mechanical boosters
can be further enhanced by the use of an External Evacuation System (EES) kit. The EES
kit will only provide performance improvement on pumpdown cycles lasting less than
30 seconds to pressures below 0.1 mbar. The EES kit must only be used on clean
applications.
Page 27
M58800880_H - Technical data
Summary of Contents for 9773512584
Page 6: ...This page has been intentionally left blank ...
Page 87: ...Figure 19 GXS160 installation drawing Sheet 4 Page 83 M58800880_H Installation drawings ...
Page 178: ...This page has been intentionally left blank ...
Page 179: ...This page has been intentionally left blank ...
Page 180: ...edwardsvacuum com ...