Figure 8 The Harting Han® 100 A axial screw module cable-mounted connector
1. Low volt pin configuration
2. High volt pin configuration
1. Low volt pin configuration
2. High volt pin configuration
A. Coding pin
B. Mounting screw
C. View from cable side: connect protective
earth into earth terminal
D. 4 mm hex (allen) key
E. Insert stranded wire
A. Coding pin
B. Mounting screw
C. View from cable side: connect protective
earth into earth terminal
D. 4 mm hex (allen) key
E. Insert stranded wire
Pin identification
Pin A1
Phase 1
Pin A2
Phase 2
Pin D1
Not connected
Pin D2
Phase 3
Torque settings for connector pins
Cable size (mm
2
)
Maximum torque setting (Nm)
10
6
16
6
25
7
35
8