background image

 

12.

 

If the browser does not auto detect the sensor(s), 
select “Search for sensors”. 

13.

 

Once the sensor is found you will see an icon on 
the  left  side  of  the  screen  for  the  rotary  motion 
sensor. The icon will display real time data. 

14.

 

Click  on  the  “Module  setup”  button  located  on 
the  rotary  motion  sensor  icon  in  the  module 
window  to  change  the  rotary  motion  probe 
settings if need be. 

15.

 

Click  on  the  experiment  set  up  button  to  change 
the  experiment  settings  if  need  be  (Experiment 
duration for example). 

16.

 

To  run  an  experiment  and  collect  data,  select 
“On-Line” experiment, then select "Run". 

17.

 

If you have a newer generation 900-268 (with the 
USB icon on the cover) this can be used as a 900-
213,  meaning  you  can  tether  the  probes  directly 
to  the  computer  using  the  900-268.  To  engage 
operation  in  this  fashion,  press  3  times  on  the 
panel  key.  Repeating  this  operation  will  return 
the unit to WiFi mode. 

 

Operation with Edu-Logger viewer 

 

Materials needed: 

 

900-236 Rotary Motion Sensor 

 

900-272 Viewing Module 

 

900-215 Battery 

 

Procedure: 

1.

 

Connect the  rotary  motion sensor to the left  side 
of the viewer. 

2.

 

Connect  the  900-215  module  to  the  right  side  of 
the viewer. 

3.

 

The 900-272 will auto detect  the sensor and  you 
will see it appear on the left side of the screen. 

4.

 

Once  the  sensor  appears  it  will  be  monitoring 
data in real time. 

Summary of Contents for 900-236

Page 1: ...Edu Logger Rotary Motion Logger Sensor Guide 900 236...

Page 2: ...n right out of the box using this guide Hundreds of possible experimental subjects that can be done with the 900 236 sensors are rotary motion studies angular velocity angular acceleration sin waves t...

Page 3: ...213 module The 900 213 module then connects to a computer via a USB to mini USB cable Please note that you cannot plug the rotary motion sensor directly into the computer Resident PC software and brow...

Page 4: ...xperiment settings if need be experiment duration for example 10 The rotary motion sensor will give a live reading in the box to the left of the screen while plugged in 11 To run an experiment and col...

Page 5: ...r 900 268 instructions or the 900 268 quick start guide please visit www edulab com 6 The 900 268 indicator lights will flash take no action until the LED to the far left turns blue this can take up t...

Page 6: ...xperiment then select Run 17 If you have a newer generation 900 268 with the USB icon on the cover this can be used as a 900 213 meaning you can tether the probes directly to the computer using the 90...

Page 7: ...Procedure 1 Connect the rotary motion sensor directly to the left side of a charged 900 215 module 2 When ready to collect data press the Start Stop button on the rotary motion sensor a red light will...

Page 8: ...ensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the rotary motion sensor to a 900 213 module they directly plug together Please note there...

Page 9: ...le rate S sec 0 to 360 16 bit 0 08 100 Rad s 345 0 6 Rad s2 32 222 11 Rev s 55 0 02 Sensor features Fully digital data Rugged plastic ergonomic case Rotary motion rotating head piece attached directly...

Page 10: ...a in the correct scientific units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The probe shaft...

Page 11: ...out of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of th...

Page 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10012013...