background image

 

Using the rotary motion sensor: 

 
The  rotary  motion  sensor  is  can  be  set  up  in  your 
classroom or lab in many different configurations: 

 

Connect  the  revolving  head  to  a  conveyor 
system. 

 

Roll the revolving head along a surface. 

 

Spin the revolving head manually. 

 

Quick start procedure: 

 

PC or Mac Computer 

 

Materials needed: 

 

900-236 Rotary Motion Sensor 

 

900-213 USB Module 

 

USB  to  mini  USB  cable  (included  with  the  900-
213 module) 

 
Your rotary motion sensor needs to be connected to a 
900-213 module.  The 900-213 module then connects 
to  a  computer  via  a  USB  to  mini-USB  cable.    Please 
note  that  you  cannot  plug  the  rotary  motion  sensor 
directly into the computer. 
 
Resident  PC  software  and  browser  based  application 
can  be  downloaded  for  free  at 

www.edulab.com

  as 

well as a full software user guide.

  

Note:

  Make  sure  not  to  download  and  install  both 

types of software they will conflict on the computer. 

 

Procedure: 

1.

 

Install the Edu-Logger software 

2.

 

Connect the 900-213 module to the PC or Mac 

3.

 

Connect the  rotary  motion sensor to the  900-213 
module (they directly plug together).  Please note 
there is no calibration required for this sensor. 

4.

 

Open the Edu-Logger software. 

Summary of Contents for 900-236

Page 1: ...Edu Logger Rotary Motion Logger Sensor Guide 900 236...

Page 2: ...n right out of the box using this guide Hundreds of possible experimental subjects that can be done with the 900 236 sensors are rotary motion studies angular velocity angular acceleration sin waves t...

Page 3: ...213 module The 900 213 module then connects to a computer via a USB to mini USB cable Please note that you cannot plug the rotary motion sensor directly into the computer Resident PC software and brow...

Page 4: ...xperiment settings if need be experiment duration for example 10 The rotary motion sensor will give a live reading in the box to the left of the screen while plugged in 11 To run an experiment and col...

Page 5: ...r 900 268 instructions or the 900 268 quick start guide please visit www edulab com 6 The 900 268 indicator lights will flash take no action until the LED to the far left turns blue this can take up t...

Page 6: ...xperiment then select Run 17 If you have a newer generation 900 268 with the USB icon on the cover this can be used as a 900 213 meaning you can tether the probes directly to the computer using the 90...

Page 7: ...Procedure 1 Connect the rotary motion sensor directly to the left side of a charged 900 215 module 2 When ready to collect data press the Start Stop button on the rotary motion sensor a red light will...

Page 8: ...ensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the rotary motion sensor to a 900 213 module they directly plug together Please note there...

Page 9: ...le rate S sec 0 to 360 16 bit 0 08 100 Rad s 345 0 6 Rad s2 32 222 11 Rev s 55 0 02 Sensor features Fully digital data Rugged plastic ergonomic case Rotary motion rotating head piece attached directly...

Page 10: ...a in the correct scientific units o C o F Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The probe shaft...

Page 11: ...out of direct sunlight Warranty We promise to deliver our sensor free of defects in materials and workmanship for a period of 3 years from the date of purchase Our warranty does not cover damage of th...

Page 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10012013...

Reviews: