VisionLink XF
Setup
9
2019 March 19
EDT, Inc.
DIP Switches and LEDs
shows the extender’s ports and features, including the DIP switches and LEDs.
Figure 3. Ports and features
•
The DIP switches indicate which device (camera or framegrabber, as labeled on the Camera Link end of the unit);
whether Power over Camera Link (PoCL) is on or off; and whether the unit is set for program mode or normal mode.
•
The LEDs indicate the status of each port.
explain the details.
a. Camera Link end
b. Fiberoptic end
Table 1. DIP switch settings
#
Function
On
Off
Details
1
Which device to connect
camera
framegrabber System reads this switch at boot time only.
2
Port 1 (P1): PoCL
P1: PoCL on
P1: PoCL off
Valid for camera-end units only. This switch always should be “off”
for the framegrabber-end unit (that is, whenever switch 1 is “off”).
3
Port 0 (P0): PoCL
P0: PoCL on
P0: PoCL off
Valid for camera-end units only. This switch always should be “off”
for the framegrabber-end unit (that is, whenever switch 1 is “off”).
4
Program vs. normal mode
program
normal
System reads this switch at boot time only.
5
undefined
--
--
--
6
undefined
--
--
--
Table 2. LED behaviors
Unit
LED location
Behavior
Meaning
Camera
SDR
Green, no flash
Good; the camera (pixel clock) is detected
Green, quick flash (10Hz)
Error; the camera (pixel clock) is not detected
Red, no flash
Good; PoCL is enabled
Red, quick flash (10Hz)
Error; PoCL is enabled, but a non-PoCL device is connected to
the unit (SafePower circuit is open)
SFP+
Green, no flash
Good; the other unit is detected at the framegrabber end
Red, slow flash (1Hz)
Error; the other unit is not detected at the framegrabber end
Red, quick flash (10Hz)
Error; the other unit is detected, but it is a camera-end unit (it
should be a framegrabber-end unit)
Framegrabber
SDR
Green, no flash
Good; data is transferring between the unit and the framegrabber
SFP+
Green, no flash
Good; the other unit is detected at the camera end
Red, slow flash (1Hz)
Error; the other unit is not detected at the camera end
Red, quick flash (10Hz)
Error; the other unit is detected, but it is a framegrabber-end unit
(it should be a camera-end unit)
SDR ports (“P0” and “P1”) with LEDs
transmit / receive
DIP switches
Power (“P4”)
SFP+ port
(“P3”) with
LED: