DynaTrol HMI Touch Screen Control
Page 9
TEMPERATURE CONTROL
Programming a temperature and the Heat button will activate the heating device. This
setting will be maintained for the duration of the step.
ROTATION CONTROL
The step programmable wash cadence is set to a default standard wash rotation. By
pressing the Rotation button a screen with six options will appear. The setting is step
local. Available selections include: Standard Wash; Delicate Wash; Fluff; Forward Only;
Reverse Only; No Rotation. When selecting Standard Wash, Delicate Wash, or Fluff a
new screen will popup with default settings which can then be accepted or modified.
DYNOZONE CONTROL
Selecting the Ozone button will activate the DynOzone system during the wash step.
System will start based on the configured step start parameters and continue for the
duration of step.
SIGNAL CONTROL
Up to 10 signal outputs (depending on model) may be programmed per step. A popup
screen allows for global naming of the signal as well as time entry. A signal time cannot
exceed step time.