5. S P E C I F I C A T I O N S
5.1. Accuracy
• ±% of reading ±number of least significant digits at 18°C to 28°C, with
relative humidity up to 75%.
• All specifications assume less than 1 year since calibration. Temperature
coefficient:
• 0.1x specified accuracy/°C.
5.2. General
• Maximum voltage: 1000V CAT II 600V CAT III
• Altitude: 2000m
• Display: LCD 3999 counts
Updates 2-3/sec
• Ranging method: Auto/manual range mode
• Polarity indication: ‘__’ display for negative polarity
• Overrange indication: LCD will display ‘OL’
• Low battery: ‘ ‘ will appears on LCD
• Jaw capability: 40mm, Max conductor size
• Power: Battery 1.5V x3 Size AAA
• Size: 225mm x 86mm x 32mm
• Operating: 5°C to 35°C
• Storage temperature: 10°C to 50°C
5.3. VOLTAGE
DC Voltage
• Input Impedance: 10M
Ω.
• Overload Protection: 1000V DC or 700V AC RMS
RANGE
RESOLUTION
ACCURACY
4V
1mV
40V
10mV
±(0.8% of rdg +5 digits)
400V
0.1V
600V
1V
±(1.0% of rdg +5 digits)
1000V
1V